Avaya C460 Manuel D’Utilisation

Page de 268
Chapter 2        Avaya C460 CLI Commands
116
Avaya C460 Reference Guide
The syntax for this command is:
set port redundancy-intervals
 <min-time-between-switchovers> 
<switchback-interval> | none
Example:
set port spantree
User level: read-write, admin.
Use the set port spantree command to enable or disable the spanning tree 
mode for specific switch ports.
The syntax for this command is:
set port spantree
 {enable|disable} [module/port]
Example:
min-time-between-switchovers
The minimum time between redundancy 
switchovers for each pair (in milliseconds).
switchback-interval
The period the primary port link has to be 
“up” before the system switches back (in 
milliseconds). 
• If switchback interval is zero, the system 
never switches back  
• If it is one, switchback occurs immediately 
after the primary port link returns
none
The system switches bank only if the 
secondary link fails.
C460-1# set port redundancy-intervals 100 20
Done!
enable|disable
Enables or disables the spanning tree mode for the  
specified ports. 
Module
Module number
Port
Port number
C460-1# set port spantree enable 3/1
port 3/1 was enabled on spantree