Appendix B
Using BOOT Loader
280
Avaya M770 ATM Switch User’s Guide
Viewing a list of fatal system exceptions 
A fatal system exception occurs when the Central Processing Unit (CPU) detects an 
error such as a division by zero, or accesses to non-existent memory. A fatal 
exception causes the M770 ATM Switch to reboot. A breakpoint is a special type of 
exception which is invoked by the M770 ATM Switch software when it detects an 
internal inconsistency.
To dump a list of fatal system exceptions, use the
system breaklog
 
command. 
Note:  
The breaklog provides vital information for diagnosing why the M770 ATM 
Switch has crashed. This information needs to be reported to Avaya Technical 
Support.
Clearing the list of fatal system exceptions 
To clear the list of fatal system exceptions, use the
system breaklog clear
 
command. 
Running all the hardware tests
You can run all the non-critical hardware tests on a M770 ATM Switch. If all the 
tests pass the M770 ATM Switch will respond with DONE! 
If a test fails, then the BOOT Loader will display the test that has the failed and the 
M770 ATM Switch LEDs will display the sequence that represents the error. For 
more information about the LED status sequence, see the Module Installation 
Guides.
To run all hardware tests, use the
system test
 
command. 
Command:
M15-155s8:/>system breaklog
Output:
Filename:
lmaux.c
Line No:
553
pml_time:
1234
Abs_time:
Unknown
Stablised Count:
0
Reason:
0000b024
epc:
c005dce4
badva:
c8681734
Command:
M15-155s8:/>system breaklog clear
Command:
M15-155s8:/>system test
Output example
when all tests pass:
Done!
Output example
when there is a failure:
The boot loader SELF-TEST failed