Avaya P330-ML-ML Manuel D’Utilisation

Page de 320
Chapter 2        Avaya P330-ML Layer 2 CLI Commands
204
Avaya P330-ML Reference Guide
Example:
snmp-server informs
User level: supervisor
Use the snmp-server informs command to configure inform parameters.
udp-port
(Optional)
Keyword that specifies that a specific UDP port on the target 
host should be used when sending notifications to the host. 
The default UDP port is 162.
port
The UDP port on the target host to which notifications are sent.
notification
-type-list
(Optional)
List of notification types. Each types combines related 
notifications. You can enable or disable notification generations 
on a per group basis. For example, the swRedundancy type 
groups new and delete software redundancy notifications.
If no notification-type-list is specified, the default, all, is used.
• all/* – All traps
• generic – Generic traps
• config – Config change notifications
• eth-port-faults – Ethernet port fault notifications
• sw-redundancy – Software redundancy notifications
• temperature – Temperature warning notifications
• cam-change – Changes in CAM notifications 
• l3-faults – Layer 3 faults, including duplicate IP and 
VLAN violations
• lag-event – Link aggregation faults and configuration 
changes
• policy – Changes in policy  notifications (for L3 devices)
• link-down-faults – ITC proprietary link down 
notifications
• supply – Power supply notifications (main and backup)
• fan – FAN faults notifications (main and backup)
• cascade – Cascade connection fault notifications.
Note that the list of notification names is proprietary to ITC.
P330-N>snmp-server host 149.49.38.221 informs v3 noauth 
charlieBrown
Done!