ATTO Technology 3400 Manuel D’Utilisation

Page de 28
7 ATTO FibreCenter 3400 
Ins
tallation and Operation Manual
4 Setting up the FC Rack System
The ATTO FC Rack System is a configurable 19-inch rack system with two bays designed to house the 
ATTO FibreCenter 3400. The 1U rackmount enclosure provides the flexibility to integrate the
ATTO FibreCenter in pairs. 
The following items are included with the ATTO 
FC Rack System: 
 ❈Up to two (2) ATTO FibreCenter modules
 ❈One (1) or two (2) power modules.
 ❈One (1) or two (2) independent cooling fans
 ❈One (1) or two (2) AC shielded power 
cord(s).
 ❈Two (2) Rackmount “L” brackets and (4) 
screws for mounting the unit into the rack.
The main enclosure of the ATTO FC Rack System 
houses all the FibreCenter modules and power 
modules: two bays for FibreCenter and two bays 
for power modules. 
Physical dimensions
Width:
17.4 inches (441.6 mm)
Depth: 
17 inches (431.5 mm)
Height: 
1.72 inches (43.7 mm)
Operating environment
Operating temperature: 
0-40° Celsius
Humidity: 
0-90% non-condensing
Mounting
You can install the ATTO FC Rack System with 
ATTO product modules facing the front or the 
back using the "L"-brackets and mounting holes 
provided on either end. The mounting holes on the 
"L"-bracket fit a standard 19-inch rack, using a 
centered 1.25-inch (31.7 mm) hole pattern.
Air flow and cooling
The FC Rack System cooling fans are contained 
within the power module. Each power module 
contains two 8-CFM fans and provides a total of 
16 CFM of airflow. A system that has two power 
modules installed will have a total of 32 CFM of 
airflow. Air enters through the sides of the 
enclosure and is exhausted out the power 
modules. Ambient air near the inlets should not 
exceed 40° C.
WARNING Do not block the vents on either side of the 
main enclosure. Blocking the vents may cause 
overheating and could damage the product.
Internal power distribution
The ATTO FC Rack System provides a redundant 
power scheme with two hot swappable power 
supply modules. Each power supply module feeds 
12V to the backplane.  From there the power is 
distributed to the FibreCenter 3400 modules and 
the fans. 
A failure of one power supply will not affect the 
functionality of the modules or the cooling system 
since the second supply will continue to supply 
power to the backplane.  In a redundant power 
supply installation, one supply can be removed 
and replaced without affecting the rest of the 
system in any way. 
The product module will detect power supply 
failures, voltage regulation and failover. 
NOTE: Power modules will load balance 
when two are present in the ATTO FC Rack 
System
The power module is a hot swappable unit that 
contains enough power to supply two ATTO 
product modules and four cooling fans. Each is 
designed to slide into the ATTO FC Rack System 
enclosure in either of the two bays on the end of 
the rack enclosure that is closer to the backplane 
and farther away from the cooling vents in the 
sides of the rack enclosure.
Input voltage: 
110/230V AC, with an operating 
input range of 90-132V AC or 175-264V ac, 47-
63Hz, single phase.  The AC input range selection 
is automatic. No manual jumper or switch over is 
required.