ATTO Technology 3400 Manuel D’Utilisation

Page de 28
11 ATTO FibreCenter 3400 
Ins
tallation and Operation Manual
6 Configuring the ATTO FibreCenter
The ATTO FibreCenter 3400 may be configured as one 8-port hub (Zone 1) or two 4-port hubs (Zone 2 
and Zone 3). Each Fibre Channel bus in the two-zone configuration can run at different speeds (1Gb or 
2Gb). The zones may be configured as either a one or two A-B style switch in a FC-AL loop. 
Configuration is managed through a 10/100 BaseT Ethernet port.
The software necessary to drive the FibreCenter 
3400 consists of two segments: the switching 
logic and the command-processing logic.
The switching logic sets up hardware 
configurations. The command-processing logic 
allows you to change parameters on the 
FibreCenter 3400 and view responses and other 
information about the hub and its performance via 
a Telnet server program and command line 
interface commands (see Chapter 7.3)
The ATTO FibreCenter 3400 may be configured 
as one 8-port hub (Zone 1) or two 4-port hubs 
(Zone 2 and Zone 3) using the Setup and Switch 
CLI commands. Each Fibre Channel bus in the 
two-zone configuration can run at different speeds 
(1Gb or 2Gb). The zones may be configured as 
either a one or two A-B style switch in a FC-AL 
loop. A zone is defined by the following 
parameters: 
 ❈A zone contains only adjacent ports.
 ❈Except for the Get Switch command return, 
Ports are labeled P1 through P8: all 
connections are assumed to be between port 
P1 and  P2 | P3 | P4 | P5 | P6 | P7 | P8  in zone 
1, between port P1 and P2 | P3 | P4  in zone 2 
and between port P5 and P6 | P7 | P8 in zone 
3. In the Get Switch command return, ports 
are labeled with letters.
 ❈Zone 2 and Zone 3 do not overlap. 
 ❈Within a zone, all ports are disabled except 
the lowest-numbered port (counting from the 
left) and the single other port to which it is 
switched.
Data transfer when setting up zones
You must temporarily stop data transfer to the hub 
when you execute the Setup and Switch 
commands during setup of the ATTO FibreCenter. 
Only the initiators can stop data transfer; the 
FibreCenter cannot stop data transfers.
 ❈If you are changing the FibreCenter 3400 
from a single-zone configuration to a dual-
zoned configuration, you must temporarily 
stop all data transfers from the host to the 
FibreCenter.
 ❈If you are changing zone 2 setup in a dual-
zoned configuration, but not changing zone 
3, you must temporarily stop all data 
transfers from the host in zone 2 but data 
transfer may continue in zone 3.
 ❈If you are changing from a dual-zoned 
configuration to a single-zoned 
configuration, you must temporarily stop all 
data from the host to the FibreCenter.
FibreCenter behavior on reset or power-up
The ATTO FibreCenter takes about 40 seconds to 
begin operation after power-up or execution of the 
Reset command. All ports are disabled during this 
40 seconds. When the FibreCenter begins 
operation, it will use its default configuration or 
the last mapping designated by the Setup and 
Switch commands.
Zone 1
The FibreCenter 3400 may be configured into one 
zone in which all eight ports are available. Up to 
seven devices may access the eighth port, one at a 
time. 
Zone 2 and Zone 3
The FibreCenter 3400 may be configured into two 
separate zones. In each zone, up to three devices 
may access the fourth port in that zone, one at a 
time. Devices in one zone may not access ports in 
the other zone.