ATTO Technology 3400 Manuel D’Utilisation

Page de 28
 Secure Data Path Applicationv  16
 7.2 Diagnostic commands
The commands in this section only provide information about the ATTO FibreCenter 3400. Access this 
information using these command line interface commands in a Telnet session over the Ethernet port. 
Status
Displays the status of the power supplies and the cooling fans.
Limits: 
PP = power supply status; OK = operating, NG=inoperable, NI = missing
FF = cooling fan status: OK = operating
K = L
Action: none
Information: get•Status•000
Return syntax: Status•000•PS1:PP•FAN1:FF•PS2: 
PP•FAN2:FF•KEY:K
Return example: 
Status•000•PS1:OK•FAN1:OK•PS2:OK•FAN2:OK•KEY:L
Telnet Status
Returns the Telnet status.
Limits: Status may be narrowed to [1] Telnet session information [2] TCP statistics or [3] Telnet auditing information
Action: none
Information: get•RACK •000•Telnet•Status• [1|2|3]
Version
Displays the firmware version of the rack. The FibreCenter 3400 has two processors. Returns reflect status of the ARM firmware and the Xilinx 
firmware.
Limits: n = ARM firmware version; x = Xilinx firmware version
Action: none
Information: get•RACK •000•Version
Return: n.nn-xxx