Firebox System Area
Hardware Guide
21
Reset Firebox passphrases when you do not know or have forgotten 
them
Fireboxes shipped before LiveSecurity System 4.1 shipped with the 
original, standard functionality called the read-only system area. 
Fireboxes shipped with LiveSecurity System 4.1 or later contain both the 
older functions and a new set of features designed to enhance usability, 
called the enhanced system area.
Read-only system area
The Firebox III has a read-only system area that the unit can be booted 
into using the serial cable shipped with the Firebox. When a Firebox is 
running from the read-only system area, the Sys B light and the Armed 
light are both illuminated.
With the Firebox running the read-only system area, use one of two 
methods to initialize the Firebox and prepare it for configuration:
Factory default switch on back
Out-of-band, using a modem
Direct, using a serial cable
However, do not attempt to use the read-only system area configuration 
file as a base or template for your working configuration. It will not work. 
You must create a new configuration file using the QuickSetup Wizard or 
open an existing configuration file.
Enhanced System Mode
By default, Firebox III boots into an Enhanced System Mode. When a 
Firebox is running from the Enhanced System Mode, the Sys A light on 
the front panel flickers yellow in a repeating pattern.
Managing flash disk memory
The Flash Disk Management Tool performs specific tasks involving the 
Firebox flash memory. The flash disk is divided into three areas:
System (SysB)– Contains a permanently stored, basic Firebox 
software image with the passphrase wg.