Fujitsu BX600 S2 Manuel D’Utilisation
PRIMERGY BX600 S2 Basic Unit
53
Preparation for Use and Operation
Switching the Blade Server ON/OFF
5.2
Switching the Basic Unit ON/OFF
V
CAUTION!
●
Make sure that the PRIMERGY BX600 S2 basic unit is connected to
the mains for at least one minute before pressing the power ON/OFF
button to switch the system ON.
the mains for at least one minute before pressing the power ON/OFF
button to switch the system ON.
●
If, after switching the basic unit ON, you can only see flickering stripes
on the attached monitor, switch the system OFF immediately (see
on the attached monitor, switch the system OFF immediately (see
●
The system ON/OFF power button does not disconnect the system
from the mains voltage. To completely disconnect it, you must remove
the power plugs from the sockets.
from the mains voltage. To completely disconnect it, you must remove
the power plugs from the sockets.
Switching ON the Basic Unit ( Basic Unit is Powered OFF)
Ê
Press the basic unit power ON/OFF button (position 2 in
) for 2 seconds. Depending on the BIOS settings, the server blades
can be switched on automatically one after another according to the slot
numbering (see
numbering (see
Ê
If necessary, switch ON the required server blades (see
The basic unit is switched ON and the activated server blades perform a system
test and boot the operating system.
test and boot the operating system.
Switching OFF the Basic Unit (System is Powered ON)
The basic unit is operating (server blades are also switched ON).
Ê
For graceful shutdown of all server blades, press the system power
ON/OFF button (position 2 on
ON/OFF button (position 2 on
) for 4 seconds. The
server blades will then be powered OFF.
Ê
For hard shutdown of all server blades, press the system power ON/OFF
button (position 2 on
button (position 2 on
) for 10 seconds. The server
blades will be powered OFF immediately.