Downloading IOLAN Firmware
Resetting the IOLAN to the Default Configuration
The RESET button is available on all IOLAN models (except medical unit models). The button 
allows you to reset the IOLAN to its Perle or custom factory default configuration. The Power/Ready 
LED color and the resetting of the IOLAN default configuration vary depending on how long you 
press and hold the RESET button, as shown in the table below.
Downloading IOLAN Firmware
To upgrade the IOLAN firmware (software):
z
In DeviceManager, select 
Tools
Advanced
Download Firmware to 
IOLAN. You can browse 
to the firmware location. Once the firmware download is complete, you will be prompted to 
reboot the IOLAN. You can choose to reboot the IOLAN at another time by selecting 
Tools
Reset
Reboot 
IOLAN. 
z
In WebManager, under the 
Administration
 option, select 
Update Firmware
. Either browse to 
the firmware file and then click the 
Upload
 button or configure the TFTP or SFTP server and 
click the 
Upload
 button. Note: If you use the TFTP or SFTP option, the specified TFTP or SFTP 
server must be on the same subnet as the IOLAN.
Upgrading the firmware does not affect the IOLAN’s configuration file or downloaded custom files.
Calibrating I/O
All I/O channels are factory calibrated and should not need recalibration during initial use. However 
should calibration be required, you can recalibrate in DeviceManager or WebManager. In 
DeviceManager, you calibrate the I/O channel(s) by selecting 
Tools
I/O Channels
Calibrate
. In 
WebManager, you calibrate the I/O channel(s) by selecting 
I/O Channels
Calibrate
Calibrating Analog Input
To calibrate an Analog input channel, read the section that applies to the type of input you are 
calibrating. Note that calibration will be done for the active channel configuration; for example, if 
Channel A1 is set to voltage, you cannot calibrate it for current. The voltage range configured for this 
channel will also dictate what is being calibrated. For example, if this channel is configured for a 
range of +/-10V, calibrating this channel will calibrate all channels which are configured for +/-10V. 
During the calibration process, you will be asked to apply the minimum and maximum configured 
range value to the channel; for example, to calibrate for voltage +/- 10V, you will be prompted to first 
apply -10V and then +10V to the channel.
Also, you cannot actively calibrate disabled channels (although, for Voltage, if you enable the 
channel and then set it for a range that has already been calibrated for another channel, it will also be 
calibrated).
When you press and 
hold the RESET 
button for...
LED color
IOLAN system status
Less than 3 seconds
Blinking amber
Reboots
Between 3 and 10 
seconds
Blinking amber, then turns 
solid amber when you 
release the RESET button
Reboots and resets the configuration to the 
factory default (either the Perle or custom 
default configuration)
Over 10 seconds
Blinking amber, then turns 
solid amber when you 
release the RESET button
Reboots and resets the configuration to the 
Perle factory default configuration