EXAMPLE #3:  
 
The following example shows the events that occur when an invalid bar code 
is sent.  This sample will load the factory default settings and then set the 
baud rate to 19200. 
 
 
FEATURE 
HOST  
COMMAND 
ASCII  
REPRESENTATION 
SCANNER 
RESPONSE 
Enter Configuration Mode  [stx]999999[etx] 02h 39h 39h 39h 39h 39h 39h 03h  [ack] or 06h 
Load Defaults 
[stx]99999:[etx] 02h 39h 39h 39h 39h 39h 3Ah 03h  [nak] or 15h 
Invalid command was sent, you must start over! 
Enter Configuration Mode  [stx]999999[etx] 02h 39h 39h 39h 39h 39h 39h 03h  [ack] or 06h 
Load Defaults 
[stx]999998[etx] 02h 39h 39h 39h 39h 39h 39h 03h  [ack] or 06h 
19200 Baud Rate 
[stx]415870[etx] 02h 34h 31h 35h 38h 37h 30h 03h  [ack] or 06h 
Exit Configuration Mode 
[stx]999999[etx] 02h 39h 39h 39h 39h 39h 39h 03h  [ack] or 06h 
The scanner will beep three times! 
 
 
 
 
This example illustrates two important points. 
 
First, if an invalid command is sent from the host, the scanner responds with 
a [nak] and the end-user must start over from the beginning. 
 
Second, if a command is sent to change the Baud Rate, the new baud rate 
does not take effect until after the end-user exits configuration mode. 
 