Industrial Controller MX001 Interface Option 
 
The MX001 Industrial Control Interface performs three functions.  
 
  Through an object sensor input, the scanner can be alerted to any package 
present in the scan field.  The sensor must have a 12V or 5V at 10mA output 
signal or switch closure (relay) output.  The MX001 can also supply 12VDC 
power at 200mA (max) to the sensor. 
(MetroSet 2 configuration required)
 
 
  The MX001 electronic switch or Triac, allows the scanner to control an 
external device directly by switching on and off a 115 VAC at 10 Amps or 
230VAC at 6 Amps output signal.  
(MetroSet 2 configuration required)
 
 
  It can alert the user that sensor conditions are not nominal (Sensor Alarm).  
 
Special configuration of the MX001 Industrial controller is necessary for 
proper installation.  Please refer to the MX001 Industrial Control Interface 
Installation and User's Guide [
MLPN
 00-02173] and the MetroSet 2 
documentation for complete details.
 
 
 
To avoid potential problems, do not power up the scanner until the 
communication cable is secured to the host.
 
 
 
Only one MX001 can be used in the primary/secondary setting  
(not shown), and it MUST be connected to the primary scanner.  
 
1.  Turn off the host system. 
 
2.  Connect the communications 
cable to the HoloTrak
®
 and to 
the host. 
 
3.  Connect the External 
MX001/Triac cable to the 
HoloTrak and the MX001. 
 
4.  Check the AC input 
requirements of the power 
supply for the scanner  
to make sure the voltage 
matches the AC outlet. 
 
5.  Connect the power supply 
to the HoloTrak.  
 
6.  Plug the power supply into 
the AC outlet. 
 
7.  Power up the host system. 
 
Refer to caution statement on page 4.