Do not install when the product (power cable) is 
electrified. 
Doing so may result in electric shocks.
Use single-phase 220-240V power.
Using the incorrect power supply may cause fires, 
electric shocks or malfunctions.
Power cable
230
207
164
57.5
Appr
ox. 500mm
267
68
635
Conduit box
Recommended 
installation heights
For men: 925mm
For women: 905mm
Power cable hole (rear face) 
Terminal block 
Appliance external shape 
79.5 103.5
Unit (mm)
10
15.5
R3.5
R3.5
7
7
Detailed view of 
installation holes
230
207
164
57.5
Mounting screws  
(Included)
Installation 
panel 
635 Recommended 
installation heights
For men: 925mm
For women: 905mm
Appliance shape
79.5 103.5
Appliance mounting 
screw position 
Unit (mm)
Installation method 
Check
□ Single-phase 220-240V power is being used. 
□ Make sure that a ground-fault circuit interrupter is installed in the fixed wiring.
□  A single wire (cable core: between 1.0mm
2
 and 2.5mm
2
) is being used for the power cable.
Make sure that a means for  
disconnection is incorporated in the fixed 
wiring in accordance with the wiring rules.
Fix the installation panel to the wall using 
the 4 mounting screws.
The position illustrated on the right is 
recommended. 
Use commercially available screw anchors when 
installing the appliance on a concrete wall.
Reinforce any walls made with materials other 
than concrete before installation. 
Leave a space of at least 130mm below 
the appliance.  
Dirt or water sucked into the appliance 
may damage it.
Follow the illustration on the right for the internal 
wiring.
28.5
15 6.5
Appliance mounting screw 
position 
Cautions
6.5
15
28.5
Caution
Warning