Wagner SprayTech Finish 250 Manuel D’Utilisation

Page de 30
18
Finish 370 / 250
GB
REPAIRS AT THE UNIT
Before mounting the new diaphragm, clean the insert as well 
as the grooved surface at the pressure insert (2) and the paint 
section (3) and wipe off  any oil.
Mounting is carried out in the reverse order.
1.  First tighten all the hexagonal bolts (1) crosswise with 
30Nm, then crosswise with 70Nm.
2.  Before starting up leave the pressure control valve in the 
open position for about 2 minutes while the motor is run-
ning (bleeds the unit). Only then close it until the noise of 
the inlet valve can be heard.
10.7 
REPLACING THE POWER CABLE 
Switch the unit off .
Before all repair work: Unplug the power 
plug from the outlet.
6
1
4
2
5
3
1
2
3
10.8 
TYPICAL WEAR PARTS
Despite the use of high-quality materials the highly abrasive 
eff ect of the paints means that wear can occur at the following 
parts:
Inlet valve (spare part Order No.: 0344700)
For replacing refer to Section 10.2
(failure becomes noticeable through  performance loss and/or 
poor or no suction)
Outlet valve (spare part Order No.: 0341702)
For replacing refer to Section 10.3
(failure becomes noticeable through performance loss and/
or poor suction) The outlet valve is usually considerably more 
durable than the inlet valve. Thorough cleaning may already 
help here.
Relief valve  (spare part Order No.: 0169248)
For replacing refer to Section 10.5
(failure is noticeable through performance loss. Furthermore 
material arrives constantly at the return hose although the 
multifunction switch is set to spraying.
This part is relatively seldom a wear part.
1.  Remove the cover (1) (a screwdriver may be helpfull to 
move the cover back from the box).
2.  Loosen the cable threaded joint (2).
3.  Loosen the wires in the mains terminal (3) .
4.  Replace the unit connecting line.
 
(only an approved power cable with the designation H07-
RNF with a splash-proof plug may be used).
5.  Connect the green/yellow wire to the contact with the PE 
sign.
6.  Connect the cover again with the earthing plug for the 
heating hose and mount it carefully (do not squeeze any 
cables!)