REPAIRS AT THE UNIT
10.10 
REMEDY IN CASE OF FAULTS
T YPE OF MALFUNCTION
WHAT ELSE?
POSSIBLE CAUSE
MEASURES FOR ELIMINATING THE MALFUNCTION
Unit does not start
Motor switch can not 
switched on
No voltage applied
Check voltage supply
Unit fuse has triggered
Let the motor cool down 
Unit does not suck in
Air bubbles exit from 
the return hose
Unit is sucking in outside 
air
Check: Suction system tightened properly? 
Cleaning connection at rigid suction tube 
screwed tight and not leaking? Inlet valve 
button leaky? -> Replace wiper and O-ring (-> 
refer to Section 10.1)
Air bubbles do not exit 
at the return hose
Inlet valve clogged
Press the inlet valve button until the stop is 
reached several times by hand
Inlet/outlet valve soiled 
/ foreign bodies (e.g. 
threads) drawn in / worn
Remove the valves and clean then (-> refer to 
Section Pkt.10.2/10.3) / replace worn parts 
Pressure control valve tur-
ned down completely
Turn the pressure control valve to the right un-
til the stop is reached
Unit does not gene-
rate pressure
Unit has sucked in
Air in the oil circuit
Bleed the oil circuit in the unit by turning the 
pressure control valve completely to the left 
(until overturning) and let it run approx. 2 – 3 
min. Then turn the pressure control valve to 
the right and set the spraying pressure (repeat 
process several times, if necessary). Process is 
assisted by positioning the unit vertically.
Unit reached pressu-
re, but the pressure 
collapses, also at the 
pressure gage, during 
spraying.
Suction fi lter clogged
Check the suction fi lter. If necessary, clean/
replace
Paint cannot be worked in 
this state. Due to its pro-
perties the paint clogs the 
valves (inlet valve) and the 
delivery rate is too low.
Dilute the paint
Unit reached pressure, 
but the pressure col-
lapses during spraying. 
pressure gage still 
shows high pressure
Clogged fi lter do not let 
enough paint pass
Check/clean the (high-pressure fi lter) gun fi lter
Tip clogged
Clean the tip (-> refer to Section 10.1)
Unit does not generate 
the max. pressure pos-
sible. Paint neverthe-
less exits at the return 
hose. 
Relief valve defective
Clean or replace the relief valve (-> refer to 
Section 10.5)