Wagner SprayTech 3.23 Manuel D’Utilisation

Page de 32
ProSpray 3.23 
11
GB
Handling the high-pressure hose
Cleaning the unit (shutting down)
6. 
Handling the high-pressure hose
Avoid sharp bending or kinking of the high-pressure hose. The 
smallest bending radius amounts to about 20 cm.
Do not drive over the high-pressure hose. Protect against sharp 
objects and edges.
Danger of injury through leaking high-pressure 
hose. Replace any damaged high-pressure hose 
immediately.
Never repair defective high-pressure hoses 
yourself!
6.1 
High-pressure hose
The unit is equipped with a high-pressure hose specially suited 
for piston pumps.
i
Only use WAGNER original-high-pressure hoses 
in order to ensure functionality, safety and 
durability.
7. 
Interruption of work
  1.  Open the relief valve, valve position PRIME
 (k circulation).
  2.  Switch the unit OFF.
  3.  Turn the pressure control knob counterclockwise to 
minimum pressure.
  4.  Pull the trigger of the spray gun in order to release the 
pressure from the high-pressure hose and spray gun.
  5.  Secure the spray gun, refer to the operating manual of the 
spray gun.
  6.  If a standard tip is to be cleaned, see Page 17, Section 
12.2.
 
  If a non-standard tip is installed, proceed according to the 
relevant operating manual.
  7.  Depending on the model, leave the suction tube or the 
suction hose and return hose immersed in the coating 
material or swivel or immerse it into a corresponding 
cleaning agent.
Attention
If fast-drying or two-component coating material 
is used, ensure that the unit is rinsed with a 
suitable cleaning agent within the processing 
time.
8. 
Cleaning the unit (shutting down)
A clean state is the best method of ensuring operation without 
problems. After you have finished spraying, clean the unit. Under
no circumstances may any remaining coating material dry and 
harden in the unit.
The cleaning agent used for cleaning (only with an igni tion point
above 21 °C) must be suitable for the coating material used.
 •  Secure the spray gun, refer to the operating manual of 
the spray gun.
Clean and remove tip.
For a standard tip, refer to Page 17, Section 12.2.
If a non-standard tip is installed, proceed according to the 
relevant operating manual.
  1.  Remove suction hose from the coating material.
 2.  Close the relief valve, valve position SPRAY (p spray).
 3.  Switch the unit ON.
  4.  Pull the trigger of the spray gun in order to pump the 
remaining coating material from the suction hose, high-
pressure hose and the spray gun into an open container.
Attention
The container must be earthed in case of coating 
materials which contain solvents.
Caution! Do not pump or spray into a container 
with a small opening (bunghole)!
Refer to the safety regulations.
  5.  Immerse suction hose with return hose into a container 
with a suitable cleaning agent.
 6.  Turn the pressure control knob into the blue zone -
pulsating pressure for unit cleaning.
  7.  Open the relief valve, valve position PRIME 
 (k circulation).
  8.  Pump a suitable cleaning agent in the circuit for a few 
minutes.
 9.  Close the relief valve, valve position SPRAY (p spray).
  10.  Pull the trigger of the spray gun.
  11.  Pump the remaining cleaning agent into an open container 
until the unit is empty.
  12.  Switch the unit OFF.
8.1 
Cleaning unit from outside
First of all pull out mains plug from socket.
Attention
Danger of short circult through panetrating 
water!
Never spray down the unit with high-pressure or 
high-pressure steam cleaners.
Wipe down unit externally with a cloth which has been immersed 
in a suitable cleaning agent.
Uncontrolled Copy