Echo PAS-265 Manuel D’Utilisation

Page de 32
P
ro
 A
ttAchment
 S
erieS
tm
17
o
PerAtor
'
S
 m
AnuAl
 
aIr
 
fIlter
Level 1.
Tools required:    25 or 50 mm (1 or 2 in.) Cleaning brush 
Parts required:   REPOWER
TM
 AIR & FUEL FILTER KIT 
1.  Close choke (Cold Start Position [
]). This prevents dirt from 
entering the carburetor throat when the air filter is removed. Brush 
accumulated dirt from air cleaner area.
2.  Remove air filter cover. Brush dirt from inside cover.
3.  Remove air filter and lightly brush debris from filter. Replace filter 
if it is damaged, fuel soaked, very dirty, or the rubber sealing edges 
are deformed.
4.  If filter can be reused, be certain it:
  • Fits tightly in the air filter cavity.
  • Is installed with the original side out.
5.  Install air filter cover.
fuel
 
fIlter
Level 1.
Tools required:    200-250 mm (8-10 in.) length of wire with one end 
bent into a hook, clean rag, funnel, and an approved 
fuel container.
Parts required:   REPOWER
TM
 AIR & FUEL FILTER KIT 
   wArning
Fuel is VERy flammable. Use extreme care when mixing, storing 
or handling.
1.  Use a clean rag to remove loose dirt from around fuel cap and  
empty fuel tank.
2.  Use the “fuel line hook” to pull the fuel line and filter from the  
tank.
3.  Remove the filter from the line and install the new filter.