Keep bulbs at least 2" (51 mm) from the sen-
sor and 2" (51 mm) from combustibles.
Lock Nuts
Mount the Light Control
  Place  the  mounting  bolt  through  the  front  of  the 
junction box cover. Push the small gasket hole over 
the mounting screw.
  Make sure the wire connectors and wires are inside 
the junction box. Align the mounting screw with the 
center hole in the mounting strap. Secure the fixture 
to the mounting strap.
  Push the rubber plug firmly into place.
  If a wet location junction box was not used, caulk the wall 
plate mounting surface with silicone weather sealant.
Lamp Shade
Set Screw
Wire the Light Control
Remove the existing light fixture.
Install mounting strap to junction box using screws 
appropriate for your junction box.
  The plastic hanger can be used to hold the fixture 
while wiring. The small end of the plastic hanger 
can be threaded through the hole in the center of 
the cover plate. The small end then goes into one 
of the slots on the mounting strap.
  Route all fixture wires through the large holes in 
the gasket as shown.
  Connect the junction box wires to the light fixture 
wires as shown. Twist together and secure with wire 
connectors.
  Adjust the bulb holders by loosening the lock nuts, 
but do not rotate the bulb holders more than 180° 
from the factory setting.
  Adjust lamp shades by loosening the set screws 
several  turns,  turn  shades  counterclockwise  and 
remove. Reinstall the shades in the desired position 
and tighten set screws.
White to 
White
Black to 
Black
Connect any fixture ground wire(s) and the cover 
plate ground screw to the junction box ground 
wire.
Gasket
Mounting 
Strap
Mounting 
Bolt
Rubber 
Plug