Heath Zenith 4162 Manuel D’Utilisation

Page de 24
2
595-5530-13
MANUAL MODE
AUTO
TEST
ON-TIME Switch at 1, 5,  
or 10 minutes
Mode Switching Summary
Flip light switch 
off for one second 
then back on*
* If you get confused while switching modes, 
turn the power off for one minute, then back 
on. After the calibration time the control will 
be in the AUTO mode.
INSTALLATION
For best performance, mount the fixture about 
6 feet (1.8 m) above the ground.
 WARNING: Turn power off at circuit 
breaker or fuse.
1. Remove two nuts.
3. Tighten screws 
finger tight.
2. Remove 
Mounting Plate.
This fixture comes with a universal mounting 
bracket. It is pre-assembled on the fixture to 
fit the majority of junction box applications.
However, if the slots on the mounting plate 
do  not  line  up  with  the  junction  box  screw 
holes:
1.  Remove the fixture mounting screws from 
the mounting plate. Note: Do not remove 
the ground screw.
2.  Attach  ground  wire  “pigtail”  to  ground 
screw on mounting plate (See Recom-
mended Grounding Method
 for additional 
information).
3.  Flip the mounting plate over.
4. Attach mounting 
plate to junction box.
Wire Path
Ground Screw