Hoshizaki JWE-2400CUA-R-25B Manuel D’Utilisation

Page de 79
2
2. JWE-2400CUA-R-25B
DISHWASHER SIDE 
BOOSTER SIDE 
3 phase 3-wire 208-230V/60Hz (±10%) / 
2 power supply lines㩷
208V : 18.4kVA(51.1A)   
230V : 22.1kVA(55.5A) 
208V : 20.6kVA(57.2A)   
230V : 25.3kVA(63.5A) 
Max Running 51.2A 
Rated Motor 9.0A 
Max Running 63.3A 
26.0A
Max 19.86kW 
Rated Motor 3.06kW   
Power Factor 84% 
Max 25.20kW 
AC SUPPLY VOLTAGE 
POWER SUPPLY CAPACITY 
AMPERAGE 
STARTING AMPERAGE 
ELECTRICAL COMSUMPTION 
HEATER 
16.80kW(230V) 
25.20kW(230V) 
RACK SIZE 
NUMBER OF LARGE DISHES / RACK 
CAPACITY 
WATER COMSUMPTION 
PASSING HEIGHT 
DIRECTION OF OPERATION 
19-3/4" × 19-3/4"(500 × 500mm) 
16 plates (9.1” DIA) 
240/200/160racks/hour㩷 adjustable in 3 steps (rotary switch) 
114Gal/hour(432L/hour), 0.48 Gal/rack(1.8L/rack) - at 240rack/hour 
20.5" (520mm) 
Right to Left 
OUTSIDE DIMENSIONS 
EXTERIOR 
DOOR
LEG 
W57.3" × D27.6" × H58.1" (W1,455 × D700 × H1,475mm) 
Stainless Steel 
Vertically Sliding Service Panel(Opening:W25.6" × H18.9") 
Stainless Steel Adjustable 9.4" - 11.0" 
Upper and Lower Fixed Spray 
Wash 1HP x 2, Rinse 0.134HP 
Draw Out Overflow Pipe, Overflow Drain 
Rack Detection (Wash/Rinse) 
Residual Heat Drying 
Filter Collection 
Not Provided 
Wash Water Temperature / Rinse Water Temperature (selectable by switch) 
Ready, Auto Fill, Wash, Error Code 
27.2Gal (103L) 
Automatic Hot Water Supply by 
Microprocessor Control 
Wash: 160ºF (71ºC) min. 
Thermistor Control: 163ºF(73㩷C) – 168㩷㪝(76C)  
12.4Gal (47L) 
Automatic Hot Water Supply by 
Water Valve 
Rinse: 180ºF (82ºC) min. 
Thermistor Control: 182ºF(83ºC)-185ºF (85ºC)
WASH SYSTEM ,RINSE SYSTEM 
PUMP  
DRAIN SYSTEM 
START 
DRY SYSTEM 
REFUSE DISPOSAL 
DETERGENT 
DISPLAY 
TANK CAPACITY 
HOT WATER SUPPLY 
TEMPERATURE CONTROL 
CONNECTION – WATER SUPPLY 
                            – DRAIN 
Inlet: 3/4"FPT   
Outlet: 1-1/2"MPT
CONTROL 
Microprocessor control 
Water Level Switch, 
Bimetal Thermostat (Manual - Reset), 
Thermistor (Auto - Reset) 
Float Switch, 
Bimetal Thermostat (Manual - Reset), 
Thermistor (Auto - Reset) 
BOIL – DRY PROTECTION 
SAFETY SYSTEM 
Service Panel Switch, Emergency Stop by Microprocessor Control 
Table Limit Switch, Emergency Stop Button, Conveyor Overload Protector 
WEIGHT 
Net 430lb (195kg) / Gross 584lb (265kg) 
PACKAGE
Carton + Crate 
W62.6"×D32.9"×H65.9" (W1,590mm ×D 835mm × 1,675mm) 
CERTIFICATION 
NSF ANSI-3, ETL, cETL, Energy Star 
ACCESSORIES-SUPPLIED 
Universal rack (19-3/4" x 19-3/4"), Instruction manual, Installation manual 
Maintenance sheet, Curtain(L), Curtain(S) x 2, Shaft - curtain(L), Shaft - curtain (S) x 2 
Guard(L), Guard(R), Hook - Drain, Table limit Switch, Upper wash spray arm, 
Operation box assembly, Cable cover, Inlet water strainer & Packing 
ACCESSORIES-REQUIRED 
Universal rack (addition), Ventilation hoods x 2, Drain Tempering Kit 
OPERATION CONDITIONS 
Ambient Temperature: 41 - 95ºF (5ºC - 35ºC), Voltage Range: Rated Voltage ±10% 
Recommends Water Hardness : 4gpg (grains per gallon) (68.5ppm) or less 
Water Supply Temperature: 110 - 167ºF (43ºC - 75ºC) ( Recommends 140 ºF (60ºC)) 
Water Supply Pressure (Gauge Static Pressure): 10 - 70PSIG (0.07 - 0.48 MPa) 
Exhaust Requirements : 200CFM(Entrance End),400CFM(Discharge End) 
* The rated properties are based on measurements at ambient temperature of 86ºF (30ºC) according to the Technical 
Requirements for Electrical Appliances. 
* We reserve the right to make changes in specifications and design without prior to notice.