- connect the tap to the vending machine, using
a copper or nylon hose, suitable for foodstuff
and resistant to the supply pressure. Should
a  flexible  hose  be  used,  it  is  necessary  to
assemble the reinforcement bearing inside,
supplied with the machine.
- Use a 3/8 gas-type connection.
6.5
Power  supply  connection
The veding mahine is designed to operate with
single phase voltage at 230 Volts and is protected
by 6,3 A delay fuses.
We suggest checking the following:
- the mains voltage of 230 V should not exceed
a ± 6% fluctuation
- the power supply is suitable to the machine
- a differential protection system is connected
The machine should be earthed in observance
with operating safety rules in force.
For  this  reason,  verify  the  system  earth  wire
connection to ascertain that it is efficient and in
compliance with national and European electric
safety standards.
If  necessary,  have  the  system  inspected  by
qualified personnel.
- The  machine  is  equipped  with  power  cord
(fig.16)
6.4
Water system connection
Before connecting the vending machine to the
water mains, make sure that the water is:
- drinkable,  if  necessary  by  means  of  a  test
laboratory certification
- has a pressure ranging between 1.5 and 8
bar,  otherwise  use  a  pump  or  a  water
pressure reducer accordingly.
- if  not  already  fitted,  install  a  tap  in  an
accessible  position,  so  as  to  separate  the
equipment  from  the  water  mains,  should  it
be necessary (fig. 14).
- let some water flow out of the tap in order to
eliminate possible traces of impurities and dirt
(fig.15).