Instructions for the installer
 
 
11 
 
3 GAS 
CONNECTION 
This appliance is suitable for installation with Natural 
Gas or ULPG (propane). Refer to page 12 for the 
relevant burner pressure and appropriate injector 
sizes. When the appliance is to be connected to 
Natural Gas then the pressure regulator supplied 
must be fitted to the gas inlet. A test point (for 
checking the gas pressure) is supplied either with 
the regulator or as a separate fitting in the case of 
ULPG (propane) appliances. 
Connection of the appliance to the gas supply must 
be in accordance with the requirements of AS5601. A 
½” BSP connector at the inlet is recommended and 
the gas supply line to the appliance must be of 
adequate length to allow sufficient withdrawal of 
 
appliance for service or disconnection and be: 
1.
 
annealed copper pipe or; 
2.
 
flexible hose according to AS/NZ1869 & be at 
least Class “B”, 10 mm diameter.
trewqertttt
 
The appliance must be installed with provision to allow the gas to be 
turned off and disconnected for servicing and removal of the appliance as 
required from the gas supply. 
Before the appliance is operated make certain all relevant parts are 
placed in the correct position. 
When the installation is completed the installation connections of 
appliance will require to be leak tested, the burner operating pressure and 
flame checked and adjusted. 
Warranty service calls do not cover these adjustments! 
To check the operating pressure of the appliance it is recommended at 
least 2 large size burners are used. Ensure appliance is secured to wall 
when installation is completed. 
N.G. The regulator supplied must be fitted to the ½ BSP thread at the rear 
of the appliance. An approved manual shut-off valve must be installed. 
The N.G. regulator must be checked and adjusted to 1.0kPa after 
installation. 
 
U.L.P.G. Can be connected to the inlet fitting directly. 
The pressure must be checked to ensure it is operating 
at 2.75kPa. A separate test point fitting must be 
 
installed between the piping & the appliance for the 
pressure to be checked to ensure it is operating at 
2.75kPa.