SERVICE TECHNICIAN INSTALLATION NOTES 
 
An Ansul® technician must charge and arm the fire suppression system 
before the ventilator blower will operate. See page 11. 
 
Installation and start up must be performed by an  Authorized            
Installation Company. 
 
Installer must complete the WARRANTY REGISTRATION  form, and 
record appliance installation particulars on the CUSTOMER SERVICE 
DATA
 form in this manual.  
 
Certain codes require cooking equipment  to be restrained with a      
RESTRAINT DEVICE.  It is the RESPONSIBILITY OF THE               
INSTALLER to check with the AUTHORITY HAVING JURISDICTION, 
in order  to ascertain the applicability of this requirement to THIS    
SPECIFIC EQUIPMENT INSTALLATION.  Any restraint device must 
allow access to the back and sides of the unit to provide for servicing 
and maintenance, and must not interfere with the operation of the FIRE 
SUPPRESSION SYSTEM. 
 
ELECTRICAL INSTALLATION
 
 
1.  This appliance must be installed by a licensed electrician in        
 
accordance with all applicable codes and ordinances. 
 
Electrical connection terminal block and ground lug are accessible 
 
by removing the right side panel. 
 
2.  Refer to the nameplate on the right side of the appliance.  Verify the 
 
ELECTRICAL SERVICE POWER.  Voltage and phase must match 
 
the nameplate specifications, and available electrical service     
 
amperage must meet or exceed the  specifications listed on page 1. 
 
Wiring must be no less than 6 AWG solid copper wire, rated for at 
 least 
90ºC. 
 
 NOTE: 
 Wire gauge, insulation type and temperature rating , as 
 
well as type, size and construction of conduit, must meet or exceed 
 
applicable specifications of local codes and of the National       
 Electrical 
Code. 
 
 
NOTE:  This appliance requires a NEMA 15-60R receptacle. 
 
3.  This appliance must be connected to a suitable building ground.  
 
The equipment ground connection is marked "    ". 
 
4.  The appliance is shipped from the factory wired for 3Ø electrical 
 
service.  Refer to the Wiring Diagram included with this appliance, 
 
and verify that field wiring conforms to this diagram. 
 
 
IMPORTANT:  This appliance is not approved for 1Ø operation.  
 
Conversion of this appliance to single-phase operation will void the 
 warranty. 
IMPORTANT! 
Verify that this VENTILATOR 
and food cooking equipment 
installation is in compliance 
with the specifications listed 
in this manual, with local 
code requirements, and in 
accordance with N.F.P.A 96 
(THE STANDARD FOR 
VENTILATION CONTROL 
AND FIRE PROTECTION 
OF  COMMERCIAL     
COOKING OPERATIONS
  - 
current edition).  
THIS IS THE                     
RESPONSIBILITY              
OF THE INSTALLER 
 
DANGER 
ELECTRIC 
SHOCK       
HAZARD 
 
ELECTRIC CONNECTIONS 
MUST BE MADE BY A     
LICENSED ELECTRICIAN 
Electrical shock will cause 
death or serious injury. 
 
CAUTION: 
ELECTRICAL 
SHOCK HAZARD 
 
The ground lug of this         
appliance must be connected 
to a suitable building ground. 
NOTE:  This appliance       
requires a dedicated 60 Amp 
electrical branch circuit     
protection. 
 
IMPORTANT: 
Contact a licensed electrician 
to install and connect      
electrical power to the        
appliance. 
 
IMPORTANT: 
Damage due to being 
connected to the wrong     
voltage or phase is NOT    
covered by warranty. 
INSTALLATION (continued) 