OPERATION 
CAUTION: 
HOT SURFACE 
 
Exposed surfaces can be hot 
to the touch and may cause 
burns. 
VENTILATOR OPERATION 
 
1.  Press the VENTILATOR POWER switch to ON.  The green      
 
VENTILATOR POWER light will glow and the blower fan will start. 
 
After a short time, if all filters are sensed as being in position and 
 
not clogged, the cooking appliance will be energized.   
 
 
During normal operation, the VENTILATOR POWER light will be 
 
the only light glowing on the upper control panel. 
 
2.  If the amber CHECK FILTER light glows, one or more filter         
 
elements is out of position.  Check the GREASE BAFFLE,       
 
PRE-FILTER and FILTER PACK for proper installation in their    
 
respective positions.  Grease baffle and filter pack position are  
 
sensed by mechanical switches.  Pre-filter position is sensed by a 
 vacuum 
switch. 
 
3.  When the amber REPLACE PRE-FILTER light glows, the pre-filter 
 
is nearing the end of its service life.  Replace the disposable    
 PRE-FILTER 
ELEMENT. 
 
4.  When the amber REPLACE FILTER PACK light illuminates, the  
 
HEPA / Charcoal filter pack is nearing the end of its service life.     
 
Replace the FILTER PACK. 
 
 
Note:  The REPLACE PRE-FILTER  and REPLACE FILTER PACK 
 
lights are a warning that the indicated filter is near the end of its 
 
service life.  The appliance will continue to operate for a period of 
 
time after the light  glows to allow continued operation through a 
 
peak period. However, the indicated filters must be replaced within 
 
a reasonably short time period or they will clog and shut down    
 
electrical power to the cooking appliance .  The ventilator blower 
 
will continue to run. 
 
5.  When the red SERVICE REQUIRED light glows, either the        
 
pre-filter or filter pack (or both) is clogged and can no longer pass  
 
sufficient air to allow further operation.  The ventilator fan continues 
 
to run, but the cooking appliance  is shut down until the underlying 
 
clogged filter situation has been corrected.  This  can occur when 
 neither 
CHANGE...FILTER indicator light is lit, if both pre-filter and 
 
filter pack are marginal.  Replacing both the pre-filter and the filter 
 
pack will remedy the situation. 
 
 Note: 
 
Replacing the pre-filter, even  though not very dirty, will often 
 
extend the service life of the more expensive filter pack. 
 
 
Reset the unit by turning the VENTILATOR POWER switch to 
 
OFF, then back ON
 
6.  A failure of incoming electrical power will cause a shut down of the 
 
unit.  After power is restored, reset the unit by turning the          
 
VENTILATOR POWER switch to OFF, then back ON
 
NOTE:  Griddle and fryer will not operate unless the fire suppression 
system is charged, and the ventilator section is operating . 
Fig. 8  Ventilator Indicator    
 
     and Warning Lights 