Pressure Regulator Conversion 
Disconnect all electrical power, at the main circuit 
breaker or fuse box. 
Shut off the gas supply to the cooktop by closing the 
manual shut-off valve. 
Adjust the pressure regulator, by following the 
instructions (see figure 19): 
•  Unscrew the cap. 
•  Place your thumb against the flat side of the 
spring retainer and press down to remove the 
retainer. 
•  Carefully look at the spring retainer to locate the 
NG or LP position. 
•  Turn the spring retainer over so that LP is 
showing on the bottom. 
•  Snap the retainer back into position. 
 
020
CAP
GASKET
NG
POSITION
LP / PROPANE
POSITION
PRESSURE
REGULATOR
Figure 19.  Pressure regulator conversion 
 
To Convert Appliance for Use with NG 
If this appliance has been converted for use with LP 
gas, each of the following modifications must be 
performed to convert the unit back to natural gas 
(NG). 
1.  REPLACE ALL LP INJECTORS with NG 
injectors following the steps described on previous 
page, observe the number stamped on the side, 
this number codes the orifice diameter and its 
correct burner location see figure 20 (save the 
injectors removed from the appliances for future 
use). 
2.  INVERT CAP IN APPLIANCE PRESSURE 
REGULATOR following the steps described on 
the previous page carefully look at the spring 
retainer to locate the NG position (see figure 19). 
3.  ADJUST LOW FLAME (see “Low Flame 
Adjustment”). 
 
After steps 1, 2 and 3 have been completed, check 
the appearance of each burner's flame at the Hi and 
Lo settings If the flames appear too large or too small, 
make sure all steps were completed correctly. 
 
019
139
160
180
114
 
Figure 20.  4 burner Model (30” wide)  
Figure 19.