Convection Heater Element
The convection heater assembly is held in place 
by  two 7-mm hex-nuts and 4 Phillips-head screws  
The convection heater element has an approximate 
resistance value of 9.5 Ω. Two Phillips-head screws 
connect the power wires to the element terminals.
The convection heater 
element is held in place 
by 4 Phillips-head 
screws. (Three screws on 
the front, and 1 screw 
on the end.)
End View of Element
ELECTRICAL TERMINAL
RELEASE/LOCKING   TAB
The convection fan motor is held in place by  3 
Phillips-head screws .
Convection Fan Motor
The convection fan motor wire leads have locking 
tabs that must be depressed to be disconnected. 
To remove each wire from the fan motor, depress 
the clip using a small blade screwdriver and pull the 
wire off the terminal as shown.
Front View of Outer Convection Fan  
The outer convection fan must be removed before 
removing the motor. The outer convection fan is 
held in place by a 7-mm nut, lockwasher, spacer 
and fl at washer.  
Convection Fan Motor
Rear View of Convection Fan