Impinger I -–1000 Series Service Manual - International 
38 
Conveyor Drive 
 
 
(Stepper) Motor 
Perform all check as in the above evaluation. If the 
time check is ok, refer to the next section. Check to 
see if the conveyor drive (stepper) motor is running. 
If motor is not running, refer to "Conveyor will not 
run" on Page 35. 
Magnet 
Check to insure that the magnet (cemented to shaft 
of conveyor drive (stepper) motor) has not been 
damaged, or come loose from motor shaft. Replace 
as needed. Hall Effect Sensor Check for any 
physical damage to Hall Effect sensor(mounted on 
conveyor drive(stepper)motor). Check all wiring 
and connections for damage. 
Time Display 
inaccurate, erratic, or 
inoperative(S/N 
Q14975 & Above1000 
Series) (S/N Q14791 & 
Above1200 Series) 
Conveyor Drive 
(Stepper)Control 
Check all connections for tightness or proper 
location and check all wiring for visible damage. 
Replace as needed. If there is still no time display, 
wire in (temporarily) a new conveyor drive control. 
If there is still no time display, reconnect original 
conveyor drive control. Replace Hall Effect Sensor.