Impinger I -–1000 Series Service Manual - International 
40 
Temperature Control Board 
Check for 120 VAC input to temperature control 
board. If not present, check wiring from fuse holder 
to temperature control board. Turn the temperature 
adjustment dial to the maximum temperature 
position Check for 120 VAC at coil of mercury 
contactor(s). Next, short the leads of thermocouple 
on the temperature control board, check for 120 
VAC at coil of mercury contactor(s). If voltage is not 
present, replace temperature control board. If 
voltage is present proceed. 
Temperature Control 
Potentiometer 
Potentiometer is 0 to 2.5K ohm. WITH POWER 
OFF: remove the leads from the temperature 
control board terminals 1, 2, and 3 and measure 
ohms from black to white leads. The ohm reading 
should be 0 to approximately 2.5K ohms as the dial 
Thermocouple Probe 
Remove thermocouple leads from the temperature 
control board, and measure the millivolt output of 
the leads. Refer to chart in adjustment section for 
proper millivolt readings. 
Mercury Contactor(s) 
Check for 120 VAC to the contactor coil. If voltage 
is present and contactor will not activate, replace 
the contactor(s). Also check each contactor for 
proper high voltage input and output. 
50 Amp Fuses 
If there is no high voltage input to the mercury 
contactor(s), check the 50 amp fuses and replace if 
necessary. 
 
Heater Elements 
Check the Amp. draw on each hot leg for proper 
load. Check the specifications plate for rating 
information. If the Amp.
 
draw is low or high, check 
the individual elements for opens, shorts, and 
proper resistance . To check resistance of the 
elements, turn off the power! Remove all leads 
from the elements and use an accurate digital 
VOM. The element resistance should be as follows: 
208V - 9.8 ohms approx. 220V - 10.5 ohms approx. 
240V - 13 ohms approx. If all readings are not 
correct, replace elements as needed. 
Oven heats with switch 
off 
Mercury Contactor(s) 
The mercury contactor has probably  malfunctioned 
in the closed position. If there is no voltage to the 
operating coil, but there is high voltage at the 
contactor output, replace the mercury contactor. 
Voltage Supply 
Check incoming voltage supply at line 1 to neutral. 
There should be a voltage reading of 120 VAC. If 
not present, check breakers. 
3 Amp Fuse 
This conveyor fuse is located on the  front panel. 
Replace if defective. 
Fuse Holder 
Check and/or Replace. 
Conveyor Switch 
Same procedure as for fan switch. 
Conveyor will not run  
(S/N 100-4389) 
D. C. Motor Control Board 
Check for 120 VAC input to D. C. control board 
across L1 and L2. Check the 3 amp fuse on the D. 
C. control board. Check for D. C. voltage at 
terminal F1 and F2. Voltage should be 10 VDC + 
10 steady. If this voltage is not present, replace D. 
C. control board. Check for D. C. voltage output to 
the motor across terminals A1 and A2  (this voltage 
should be approx. 125 VDC at maximum conveyor 
motor speed).