Time/Temp Display 
12.6 VAC Power Supply 
Measure the transformer primary inoperative for a 
nominal 120 VAC input. Measure the secondary 
voltage output which will be 12.5 to 15 VAC 
normally. Recheck secondary output at rear of 
Time/Temp Display. Terminals 1 to 3 should read 
12.5 to 15 VAC. Terminals 1 to 2 and 2 to 3 should 
be exactly 1/2 of the reading across 1 to 3. If you 
do not get the above secondary readings, replace 
the transformer. If 120 VAC primary voltage is not 
available, refer to the schematic and trace circuit 
for incoming power failure. There is a 4 amp fuse in 
each red secondary lead. These may be jumpered 
(for test only) to determine if they are defective or 
intermittent. 
NOTE: 
(Dual Belt Ovens) 
Dual belt ovens utilize a double pole double throw 
switch, which allows either of the optical encoders 
to be read from a single Time/Temp. Display. 
Check switch and replace as needed. 
NOTE:  Time/Temp displays 
use two types of temperature 
sensor, Thermistor Probe – 2 
yellow wires Thermocouple 
Probe 1 red wire and 1 white 
wire 
Place your pyrometer thermocouple into the center 
between fingers T2 and T3 in the oven. Disconnect 
the yellow tipped thermistor leads from the 
time/temp. terminals 9 and 10. Measure the 
resistance of the thermistor probe. See chart on 
page 72 for proper resistance readings. 
Thermistor Probe 
Inspect the thermistor bulb for its proper location in 
its spring holder. Check for short in leads where 
they enter the sensor bulb. Also check each 
thermistor lead for short to ground. 
Thermocouple Probe 
Place your pyrometer thermocouple into the center 
between fingers T2 and T3 in the oven. Connect 
temperature meter to thermocouple at terminals 9 
& 10 on back of the time/temp display (Be sure to 
maintain proper polarity on thermocouple 
connections.)  Compare actual oven temperature 
with the reading at the time/temp display.  If the 
temperature readings match, recalibrate or replace 
time/temp display.  If the readings do not match, 
replace thermocouple probe. 
Erratic time/temp display 
If strange or unusual behavior is experienced such 
as a rolling of numbers, lock up at a given number, 
first check for a display circuit lock up. This can be 
caused by a voltage spike or surge. To eliminate 
this condition remove power from the time/temp. 
display by shutting off the main fan switch, or if 
display stays on, (older models) circuit breaker 
interruption may be required. This should eliminate 
the problem. If the problem continues, jumper the 
two fuses in the red wires leading from the 12.6 
VAC transformer to the display. If this does not 
solve the problem, it may be coming in through the 
commercial power lines. Suggest that customer 
contact his power company for evaluation. 
Temp Display out or 
inaccurate 
Temp Display inaccurate 
erratic, or inoperative 
Perform the power supply check, the thermistor 
probe check, and then perform the time/temp 
simulator test. Refer to page 72 for instructions. 
Remember, when using the time/temp simulator, 
remove all the leads from the back of the display 
except the 3 power leads. After completion of this 
test and if reinstalling back into the oven, the dip 
switches must be reset for oven operation.