TROUBLESHOOTING / GAS OVENS 1033, 1034, 1046, 1047 
 
SYMPTOM
 
POSSIBLE CAUSE
 
EVALUATION
 
Incoming Power Supply
 
Check breaker/reset if required. Call Power 
Company if needed. In these ovens, there is a 
control circuit step-down transformer. This 
transformer steps down supply voltage to 120 VAC. 
If main fan will not run, the secondary of this 
transformer must be checked for 120 VAC output. 
Check specific oven model schematic for circuit 
location.
 
Transformer Fuse 
Check and/or replace. 
Fuseholder 
Check and/or replace. 
Fan Switch 
Check continuity between switch terminals. 
Oven Start Relay 
Check for 120 VAC to the relay coil. If voltage is not 
present, trace wiring back to the fan switch. If 
voltage is present, check to insure contacts are 
closing. 
20 Minute Time Delay 
Check for 120 VAC at terminal #1 to neutral on the 
20-minute timer. If no voltage is present, trace 
wiring back to the power supply. If voltage is 
present at terminal #1, check for 120 VAC at 
terminal #2 to neutral. If no voltage is present, and 
the oven start relay is closed, replace the 20-
minute timer. 
Oven Fan Relay 
Check for 120 VAC to coil of the oven fan relay. If 
no voltage is present, trace wiring back to terminal 
#2 of the 20-minute timer. Check for 120 VAC at 
terminals #2 and 6 of the relay, if no voltage is 
present, trace wiring back to the power supply. If 
voltage is present at the relay coil, check to insure 
the contacts are closing. 
Fan Fuse 
Check, replace if necessary. 
Fuseholder 
Check, replace if necessary. 
Capacitor 
Check for opens, shorts, or grounds. 
Oven fan will not run
 
Motor 
Check for opens, shorts, or grounds. WITH 
POWER OFF: turn the fan blade to check for 
locked rotor. 
20 Minute Time Delay 
Check for 120 VAC at terminal #2 to neutral while 
oven is "on". Turn off the main fan switch, 120 VAC 
should continue to be present for 20 minutes. If 
voltage is not present for approx. 20 minutes, 
replace the timer. 
No main fan cool down 
Oven Fan Relay 
Check if relay is operating and that the contacts 
remain closed during the 20 minute cool down. 
Oven Start Relay 
Contacts should open when main fan switch is 
turned off. 
20 Minute Time Delay 
120 VAC at terminal #2 should discontinue 
approximately 20 minutes after main fan is 
switched off. If the oven start relay contacts are 
open, and the voltage continues at terminal #2 of 
the 20 minute timer, replace the timer. 
Main fan runs after 20 
minute cool down 
Oven Fan Relay 
Check to insure that the contacts are opening after 
the coil is de-energized. 
No control box cooling  Fan Switch Oven Start 
Relay20 Minute Time Delay 
Oven Fan Relay Cooling 
Fans 
(SEE MAIN FAN WILL NOT RUN) 120 VAC should 
now be at this motor. If voltage is present, check 
motor for shorts, opens, or grounds. WITH POWER 
OFF: check for locked rotor.