Temperature Control 
 
Check for 120 VAC across L1 and L2 on 
temperature control board. If no voltage is present, 
retrace wiring back to power supply. Turn the 
temperature adjustment knob to the maximum 
temperature position and check for 120 VAC at the 
load terminal to neutral. If 120 VAC is not present, 
proceed as follows: If 120 VAC is present and unit 
is not heating, see "Solenoid Valve." 
Thermocouple Probe 
Remove thermocouple leads from the temperature 
control board and measure the millivolt output of 
these leads. Refer to chart on page 59 for proper 
readings. If the thermocouple probe checks good, 
then the problem is usually with the temperature 
control board. 
Solenoid Valve 
If output voltage is present at temperature control 
board, check for voltage at solenoid valve. If 
voltage is present, listen for valve to open and 
close. Also check for opens, shorts in coil. Replace 
as needed. 
Temperature Control 
Check for 120 VAC across L1 and L2 on 
temperature control board. If no voltage is present, 
retrace wiring back to power supply. Turn the 
temperature adjustment knob to the maximum 
temperature position and check for 220 VAC at the 
load terminal to neutral.  If 220 VAC is not present, 
proceed as follows: If 220 VAC is present, and unit 
is not heating, see "Flame Monitor". Check for 220 
VAC at terminal "COM" on temperature control 
board.  If no voltage is present, trace wiring back to 
ignition control. 
Thermocouple Probe 
Remove thermocouple leads from the temperature 
control board and measure the millivolt output of 
these leads. Refer to chart on page 59 for proper 
readings. If the thermocouple probe checks good, 
replace temperature control. 
Flame Monitor 
Check for 220 VAC at terminal #1. If no voltage is 
present, trace wiring back to temperature control. 
Check for 220 VAC output at terminal #8. NOTE:  
There is a delay of up to 2 seconds for 220 VAC 
output at terminal #8.  If there is no voltage output 
at terminal #8, check the reset button.  Replace 
control as needed. 
Relay, Main Burner 
Check for 220 VAC at relay coil, if no voltage is 
present, trace wiring back to flame monitor. Check 
for 120 VAC to relay contacts. If no voltage is 
present, trace wiring back to power supply. Check 
to ensure contacts are closing. Replace relay as 
needed. 
Indicator light is on, 
but no main flame 
(1033-1034) 
Valve, Temperature 
Regulation 
Check for 120 VAC at valve, if no voltage is 
present, trace wiring back to relay. If voltage is 
present, listen for valve to open and close. Check 
for opens or shorts in coil. Replace as needed.