Lincoln Series 1200 Manuel D’Utilisation

Page de 112
Impinger I -–1000 Series Service Manual - International 
47 
Incoming Power Supply 
Check circuit breakers, reset if required. Call the 
Power Co. if needed. 
Fuse Transformer 
Check, replace if necessary. 
Fuseholder 
Check, replace if necessary. 
Cooling Fan Thermostat 
Check the cooling fan thermostat (Thermostat 
closes at 120°F and opens at 100°F). With the 
cooling fan thermostat pre-heated, check for 
continuity. If switch is open, replace. 
No automatic control 
box cooling 
Cooling Fan 
120 VAC should now be at this motor. If voltage is 
present, check motor for shorts, opens, or grounds. 
WITH POWER OFF: check for locked rotor. 
Cooling fan continues 
to run after 20 minute 
cool down 
Cooling Fan Thermostat 
Thermostat is normally open and may have closed 
if control box temperature is 120°F or above. 
Gas Supply 
Check for adequate gas supply to oven. 
Manual Gas Shut-off Valve 
Check to see that manual shut-off valve is open. 
Fan Switch Main Oven Fan 
Check to see that the fan switch is on. Check if 
main oven fan is operating. If not, refer to "Oven 
fan will not run." 
Oven Start Relay 
Check for contacts to close. 
Burner Switch 
Check for 220 VAC to neutral on both sides of 
switch. 
Air Pressure Switch 
Check for 220 VAC on both sides of switch. If 
voltage present on one side only, check for air tube 
blockage. Adjust air switch. If above fails, replace 
air pressure switch. 
Gas Pressure Switch  
Check for 220 VAC to neutral on both sides of 
switch. If voltage is present on one side of switch 
only, check the following. Check for proper gas 
pressure supply to gas valve.(Marked on oven spec 
plate). Check for proper adjustment of gas pressure 
switch. Should be set at 8.8 for Nat., 23 for L.P. 
Check gas filter in gas valve for blockage or 
damage. (See Adjustment Section for location).   If 
the above checks okay, but switch still not closed, 
replace gas valve. 
Hi-Limit Thermostat 
Terminals are normally closed. If open, reset and 
test oven for proper operation. If thermostat will not 
hold for maximum oven temperature, and oven is 
not exceeding temperature dial setting, check for 
proper location of capillary bulb in its spring holder. 
If above checks okay, replace hi-limit thermostat. 
Ignition Control 
Check for 220 VAC supply to ignition control at pin 
#1 and neutral. If voltage is not present, retrace 
wiring back to hi-limit thermostat. Check for 220 
VAC at pin #6 to neutral.(Power to burner motor). If 
voltage is present, proceed. If no voltage is 
present, wait 30 seconds and check reset button. If 
above fails, replace ignition control. 
Oven will not heat 
Burner Blower Motor 
Check for 220 VAC supply to burner blower motor. 
WITH POWER OFF: turn blower wheel to check for 
locked rotor. If 220 VAC is present and motor does 
not run, replace motor. 
 
Burner Blower Motor Air 
Pressure Switch 
Check for 220 VAC switching to pin "N.O." as the 
air pressure switch closes. For Honeywell ignition 
control only, connect a temporary jumper wire (for 
testing purposes only) from pin "C" to pin "N.O." on 
ignition control (to bypass air switch). Check for air 
tube blockage or misalignment, adjust air pressure 
switch. If the above fails, replace air pressure 
switch.