DC Motor Control Board 
Check for 120 VAC input to the control board at 
terminals L1 and L2. If not present, check the 
conveyor switch and wiring back to 3-amp fuse and 
then back to power source if necessary. If 120 VAC 
is present at L1 and L2, check the VDC output at 
terminals A+ and A-. If a DC voltage is not present, 
check the 4 amp and the 1 amp fuses on the 
control board. Also reset and check the mini 
breaker in the armature line to the gearmotor. If 
120 VAC is present at terminals L1 and L2, but DC 
voltage is not present at A+ and A-, providing the 1 
amp and 4 amp fuses are good, replace the board. 
If DC voltage is present at A+ and A-, but motor 
does not run, check gear motor as follows. 
Conveyor Gear Motor 
If DC voltage is present at A+ and A- and the motor 
does not run, first check the mini breaker and then 
the conveyor. Refer to the next possible cause. 
Check the leads to the motor for evidence of any 
shorts or opens, and each lead to ground. If the 
motor fails the above tests, replace motor. Remove 
dust cover from the top of the motor and rotate 
motor shaft to determine if there is a locked rotor or 
a locked gearbox (use care so encoder disc is not 
damaged). 
 
Conveyor 
Check for any mechanical misalignment or 
improper adjustment. Also check for worn bearings. 
The Installation and Operations Manual shows 
proper conveyor belt adjustment. A conveyor belt 
that is over tightened will cause excessive bearing 
wear and sometimes, irregular speed. 
Power Supply 
Check power supply at the DC control board for the 
120 VAC at board terminals L1 and L2. If voltage is 
not present, check main circuit breakers. 
Conveyor speed 
varying or intermittent 
Tach generator and DC Motor 
Control Board 
With the power to the DC motor control board 
turned off, remove the leads from terminals T1 and 
T2.Place the test leads of a digital meter on the 
tach leads, turn power on, and the meter reading 
should be approximately 30 to 35 VDC. This 
reading should be steady within ± 0.2 to 0.3 VDC. If 
this reading is not within + 0.5 VDC, place the test 
meter probes on terminals A+ and A-. The meter 
reading should be approximately 150 to 160 VDC 
and steady within approximately 2 VDC. If the tach. 
voltage is unsteady, and the board output is steady, 
check the coupling for loose set screws or any type 
of damage. If the coupling checks good, the tach. is 
usually bad. If the board voltage output is unsteady 
beyond limits, then the board is probably bad. 
Always check the speed pot. Be sure it is okay 
before changing a board or tach. This test is not 
always 100% accurate as this test is not performed 
at operating speeds. However, this test is the best 
method currently available. Readjustment should 
always be attempted at least once before 
replacement. See procedure for board adjustment 
on page 65. 
 
DC Gearmotor 
If the DC control board is steady  then the problem 
may be the motor or gearbox. Check the brushes in 
the motor for excessive arching and/or unusual 
wear. Check the motor and gearbox from 
instruction located on page 34 under "possible 
cause" listing "Conveyor gear motor".