Lincoln Series 1000 Manuel D’Utilisation

Page de 112
Impinger I -–1000 Series Service Manual - International 
43 
Voltage Supply 
Check incoming voltage supply at Line 1 to neutral. 
There should be a voltage reading of 120 VAC. 
Fan Switch 
See procedure for checking on page 26. 
Conveyor Switch 
Check for 120 VAC to conveyor switch. If no 
voltage is present, trace wiring back to the fan 
switch. WITH POWER OFF: Check continuity 
between switch terminals. 
Conveyor Fuse (3A) 
Check, replace if necessary. 
Fuseholder 
Check, replace if necessary. 
Conveyor Control(Stepper) 
Transformer 
Check for 120 VAC supply to primary of 
transformer, if voltage is not present, trace wiring 
back to the fuse-holder. If voltage is present, check 
for output voltage from the transformer secondary. 
NOTE: this control transformer outputs (2) 
secondary voltages. Red Leads 29 VAC Brown 
Leads 10 VAC If BOTH secondary voltages are not 
present, replace the transformer. 
Speed Adjustment 
Potentiometer 
This is a 0 to 50k ohm,10 turn potentiometer. WITH 
POWER OFF: remove the 3 pin potentiometer 
cable plug from the motor control board. With a 
digital multimeter, check the ohm reading across 
the red lead to the black lead, this reading should 
be 50k ohms ± 5% as the potentiometer is rotated 
through its 10 turn rotation. Place the meter leads 
on the red lead and white lead. Rotating the 
potentiometer slowly, from low to high, the meter 
should show an even transition from 0 to 50K ohms 
± 5% through the 10 turn rotation of the 
potentiometer. There should be no dead or open 
spots through the 10 turns of the potentiometer. 
Check all three leads to ground. There should be 
no continuity to ground. If any of the above checks 
fail, replace the potentiometer. 
Conveyor Motor(Stepper) 
Control 
NOTE: if the conveyor drive motor becomes 
jammed or begins to run at an uncontrolled speed, 
the conveyor motor will stop running. To reset, turn 
off the conveyor switch, wait 10 seconds, turn the 
conveyor switch on.  If the motor does not run after 
attempting re-set, check for 2-29 VAC across the 
motor terminals 1 to 2 and 3 to 5 on the conveyor 
motor control. If voltage is not present at both sets 
of terminals, replace control 
Conveyor will not 
run(S/N Q19078 & 
Up1000 Series) (S/N 
Q14791 & Up1200 
Series) 
Conveyor Drive (Stepper) 
Motor 
Check the drive sprocket on motor out-put shaft to 
insure that it is tight.. Check motor windings – 
measurements should be approximately 2 ohms. 
Terminal 1-5, 2-6, 3-7, 4-8 WITH POWER OFF: 
Turn the motor shaft to check for jammed gear box.  
If motor shaft will not turn, replace conveyor 
drive(stepper) motor.