Lincoln 1634-000-EA Manuel D’Utilisation

Page de 32
Low Profile – 1600 Advantage Series Service Manual – International 
10 
 
 
 
 
gear motor 
 
 
and the motor does not run, first check 
 
 
 
 
 
 
 
 
the mini breaker and then the conveyor. 
 
 
 
 
 
 
 
 
Refer to the next possible cause. Check  
 
 
 
 
 
 
 
 
the leads to the motor for evidence of 
 
 
 
 
 
 
 
 
any shorts or opens , and each lead to  
 
 
 
 
 
 
 
 
ground. Check motor brushes . From  
 
 
 
 
 
 
 
 
the top of the motor, rotate motor shaft 
 
 
 
 
 
 
 
 
to determine if there is a locked rotor 
 
 
 
 
 
 
 
 
or a locked gearbox (use care so magnet 
 
 
 
 
 
 
 
 
and Hall Effect sensor board are not 
 
 
 
 
 
 
 
 
damaged). Replace motor as needed. 
 
 
 
 
Conveyor 
 
 
Check for any mechanical misalignment. 
 
 
 
 
 
 
 
 
Also, check for worn bearings.  
 
 
 
 
 
 
 
 
A conveyor belt that is over tightened 
 
 
 
 
 
 
 
 
will cause excessive bearing wear and 
 
 
 
 
 
 
 
 
sometimes, irregular speed. 
Conveyor speed varying  
Power supply   
 
Check power supply at the D.C. control 
or intermittent    
 
 
 
 
 
board for supply voltage at board terminals  
 
 
 
 
 
 
 
 
L1 and L2. 
 
 
 
 
Motor control board 
 
Place the test meter probes on terminals 
 
 
 
 
 
 
 
 
A+ and A-. (with speed potentiometer 
 
 
 
 
 
 
 
 
set to maximum speed – approximately 
 
 
 
 
 
 
 
 
2 min.). The meter reading should be 
 
 
 
 
 
 
 
 
approximately 100VDC(
±
3%), if  
 
 
 
 
 
 
 
 
voltage is not steady within limits, 
 
 
 
 
 
 
 
 
then the board is usually bad. 
 
 
 
 
 
 
 
 
Always check the speed potentiometer, 
 
 
 
 
 
 
 
 
be sure it is OK before changing a 
 
 
 
 
 
 
 
 
control board. This test is not always  
 
 
 
 
 
 
 
 
100% accurate as this test is not  
 
 
 
 
 
 
 
 
performed at operating speeds, However, 
 
 
 
 
 
 
 
 
this test is the best method currently 
 
 
 
 
 
 
 
 
available. 
 
 
 
 
D.C. Gearmotor  
 
If the D.C. control board is steady, 
 
 
 
 
 
 
 
 
then the problem may be the motor or  
 
 
 
 
 
 
 
 
gearbox. Check the brushes in the  
 
 
 
 
 
 
 
 
motor for excessive arching or  
 
 
 
 
 
 
 
 
unusual wear. Check the motor and  
 
 
 
 
 
 
 
 
gearbox from instructions located on 
 
 
 
 
 
 
 
 
page 9 under “possible cause”  
 
 
 
 
 
 
 
 
listing “conveyor gear motor” 
 
 
 
 
Magnet  
 
 
Check to insure that the magnet  
 
 
 
 
 
 
 
 
(cemented to shaft of conveyor drive  
 
 
 
 
 
 
 
 
motor) has not been damaged, or come 
 
 
 
 
 
 
 
 
loose from the motor shaft. Replace 
 
 
 
 
 
 
 
 
as needed.  
 
 
 
 
Hall Effect  
 
 
Check for any physical damage to    
 
 
 
 
Sensor   
 
 
hall effect sensor (mounted on  
 
 
 
 
 
 
 
 
conveyor drive motor). Check all  
 
 
 
 
 
 
 
 
wiring and connections for tightness 
 
 
 
 
 
 
 
 
and proper location. Replace as needed. 
 
 
 
 
 
 
 
 
Connect new hall effect to system  
 
 
 
 
 
 
 
 
and check for steady operation. 
Temperature display 
 
Display transformer 
 
Measure the transformer primary 
inoperative  
 
 
 
 
 
 
for supply voltage input. If voltage is  
 
 
 
 
 
 
 
 
not present, trace wiring back to the 
 
 
 
 
 
 
 
 
fan relay. If voltage is present,  
 
 
 
 
 
 
 
 
measure the secondary output of the 
 
 
 
 
 
 
 
 
transformer. Voltage across terminals 
 
 
 
 
 
 
 
 
1-3 should be 12-15VAC. Terminals 
 
 
 
 
 
 
 
 
1-2 and 2-3 should be ½  the voltage  
 
 
 
 
 
 
 
 
reading from terminals 1-3. If the above