Lincoln 1450 Manuel D’Utilisation

Page de 24
Impinger I – 1450 Series Service Manual - Domestic 
7
 
Control transformer 
Check for 120VAC supply to the primary of the control 
transformer. If no voltage is present, trace wiring back 
to the oven power switch. If voltage is present, check 
foe 24VAC at the transformer secondary. If there is 
primary voltage, but no secondary voltage, replace 
control transformer.  
 
Conveyor motor 
Check for 120VAC supply to conveyor motor at wire #6 
to neutral. If no voltage is present, trace wiring back to 
oven power switch. If voltage is present and motor will 
not run, check the motor windings for opens or shorts. 
WITH POWER OFF: Check the motor windings as 
follows: 
Grey to black - 38
Ω approx. 
Grey to blue - 38
Ω approx. 
Blue to black - 75
Ω approx. 
If any of the above fails, replace conveyor motor. 
 
Capacitor, conveyor motor 
Check for shorts or grounds. Replace capacitor as 
needed. 
WARNING: Capacitor has a stored charge, discharge 
before testing. 
 
Switch, conveyor reversing 
Check continuity between switch terminals. Replace as 
needed. 
 
Oven control 
If there is 120VAC supplied to the motor, and the 
motor, capacitor, and reversing switch check good, 
replace the oven control. 
Conveyor motor runs, 
but there is no speed 
display 
NOTE: Display will indicate 
“BELT JAM” 
 
 
Oven control 
Check for output voltage from oven control to hall effect 
sensor (sensor is located in conveyor motor). Measure 
voltage at the motor connector, red wire and yellow 
wire. Voltage should be approx. 10VDC. If no voltage is 
present, trace wiring back to oven control. If there is no 
voltage present at the oven control, replace the oven 
control. 
 
Conveyor motor 
If there is voltage supplied to the hall effect sensor, 
check for a frequency output from the hall effect 
sensor. Measure frequency across the yellow and white 
wires at the motor connector. Frequency reading 
should be approx. 25 – 100 Hz. If these readings are 
not achieved, replace conveyor motor. If these readings 
are achieved, proceed. 
 
Oven control 
If the hall effect sensor readings are correct, but there 
is no speed indicated on the display, replace the oven 
control.