INSTALLATION CODES AND STANDARDS
Your Vulcan fryer must be installed in accordance with:
1. State and local codes.
2. The National Electrical Code, ANSI/NFPA No. 70 (latest edition). Copies may be obtained from The
National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
3. NFPA Standard #96.
LEVELING
Place a carpenter's level on top of the fryer and level the fryer front-to-back and side-to-side by turning
the adjustable legs. If your fryer is equipped with the optional non-adjustable casters, the fryer must
be placed on a level surface.
the adjustable legs. If your fryer is equipped with the optional non-adjustable casters, the fryer must
be placed on a level surface.
ELECTRICAL CONNECTIONS
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE
APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL
ELECTRICAL CODES.
APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL
ELECTRICAL CODES.
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE
DISCONNECT SWITCH TO INDICATE THAT YOU ARE WORKING ON THE CIRCUIT.
DISCONNECT SWITCH TO INDICATE THAT YOU ARE WORKING ON THE CIRCUIT.
Place fryer as near to its final position as possible. Connect 3-phase line to X, Y and Z of terminal block.
To reach terminal block, remove electric cover plate.
To reach terminal block, remove electric cover plate.
For each 15
1
/
2
" section, a 3-phase supply line capable of handling 16 KW at the fryer's rated voltage
(208, 240, 480) is required. A hood ventilator interlock should be connected to 1 and 2 on the 4-pole
barrier strip. 1 and 2 go to a set of dry contacts on the power switch. (
barrier strip. 1 and 2 go to a set of dry contacts on the power switch. (
3
/
4
HP fan maximum, if needed.)
A wiring diagram is located inside the front door panel.