INSTALLATION CODES AND STANDARDS
Your Vulcan fryer must be installed in accordance with:
1. State and local codes.
2. The National Electrical Code, ANSI/NFPA No. 70 (latest edition).  Copies may be obtained from The
National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
3. NFPA Standard #96.
LEVELING
Place a carpenter's level on top of the fryer and level the fryer front-to-back and side-to-side by turning
the adjustable legs.  If your fryer is equipped with the optional non-adjustable casters, the fryer must
be placed on a level surface.
ELECTRICAL CONNECTIONS
WARNING:  ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE
APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL
ELECTRICAL CODES.
WARNING:  DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE
DISCONNECT SWITCH TO INDICATE THAT YOU ARE WORKING ON THE CIRCUIT.
Place fryer as near to its final position as possible.  Connect 3-phase line to X, Y and Z of terminal block.
To reach terminal block, remove electric cover plate.
For each 15
1
/
2
" section, a 3-phase supply line capable of handling 16 KW at the fryer's rated voltage
(208, 240, 480) is required.  A hood ventilator interlock should be connected to 1 and 2 on the 4-pole
barrier strip.  1 and 2 go to a set of dry contacts on the power switch.  (
3
/
4
 HP fan maximum, if needed.)
A wiring diagram is located inside the front door panel.