Motorola 700/800-Series Manuel D’Utilisation

Page de 153
1-14
Board Level Hardware Description
1
Block Diagram
Refer to 
series MVME162LX.
Functional Description
This section contains a functional description of the major blocks on 
the MVME162LX. 
Front Panel Switches and Indicators
There are two switches and four LEDs on the front panel of the 
MVME162LX.
RESET
 switch. Resets all onboard devices (including IP 
modules, if installed) and drives SYSRESET* if the board is 
system controller. The 
RESET
 switch may be disabled by 
software.
ABORT
 switch. When enabled by software, the 
ABORT
 switch 
generates an interrupt at a user-programmable level. It is 
normally used to abort program execution and return to the 
162Bug debugger.
FAIL
 
LED (red). Lights when the BRDFAIL* signal line is 
active or when the processor is halted. Part of DS1.
RUN
 
LED (green or amber). Lights when the local bus TIP* 
signal line is low. This indicates one of the local bus masters 
is executing a local bus cycle. Part of DS1.
SCON
 
LED (green). Lights when the VMEchip2 in the 
MVME162LX is the VMEbus system controller. Part of DS2.
FUSES
 
LED (green). Lights when +5Vdc, +12Vdc, and -12Vdc 
power is available to the LAN and SCSI interfaces and IP 
connectors. Part of DS2.