Motorola 700/800-Series Manuel D’Utilisation

Page de 153
Hardware Preparation
2-3
2
MVME162LX embedded controllers are factory tested and shipped 
with the default configurations listed above and described in the 
following sections. The MVME162LXÕs required and factory-
installed debug monitor, MVME162Bug (162Bug), operates with 
those factory settings.
System Controller Select Header (J1)
The MVME162LX is factory-configured as a VMEbus system 
controller by a jumper across J1 pins 1 and 2. If you select the 
ÔÔautomaticÕÕ system controller function by moving the jumper to J1 
pins 2 and 3, the MVME162LX determines whether it is the system 
controller by its position on the bus. If the board is in the first slot 
from the left, it configures itself as the system controller. If the 
MVME162LX is not to be system controller under any 
circumstances, remove the jumper from J1. When the board is 
functioning as system controller, the 
SCON
 LED is turned on.
Note
For MVME162LXs without the optional VMEbus 
interface (i.e., with no VMEchip2), the jumper may be 
installed or removed without affecting normal 
operation.
1
2
3
1
2
3
J1
1
J1
Not system controller
2
3
J1
Auto system controller
System Controller
(Factory 