Magnetek Quattro DC Elevator Drive Manuel D’Utilisation

Page de 126
Quattro DC Drive S-Curves A2 
 
 
 
Parameter Description 
Units Default
Range 
Hidden
Item 
Run 
lock
out
ft/s
2
 
7.99 
0.00 – 7.99 
ACCEL 
RATE 0 
Acceleration rate limit 
m/s
2
 2.435 0.000 
– 
3.999 
N Y 
ft/s
2
 
7.99 
0.00 – 7.99 
DECEL 
RATE 0 
Deceleration rate limit 
m/s
2
 2.435 0.000 
– 
3.999 
N Y 
ft/s
3
 
0.0 
0.0 – 29.9 
ACCEL 
JERK IN 0 
Rate of increase of acceleration, up to ACCEL 
RATE, when increasing elevator speed 
m/s
3
 0.000 0.000 
– 
9.999 
N Y 
ft/s
3
 
0.0 
0.0 – 29.9 
ACCEL 
JERK OUT 0 
Rate of decrease of acceleration to zero when 
approaching contract elevator speed 
m/s
3
 0.000 0.000 
– 
9.999 
N Y 
ft/s
3
 
0.0 
0.0 – 29.9 
DECEL 
JERK IN 0 
Rate of increase of deceleration, up to DECEL 
RATE, when decreasing elevator speed 
m/s
3
 0.000 0.000 
– 
9.999 
N Y 
ft/s
3
 
0.0 
0.0 – 29.9 
DECEL 
JERK OUT 0 
Rate of decrease of deceleration to zero when 
slowing the elevator to leveling speed 
m/s
3
 0.000 0.000 
– 
9.999 
N Y 
ft/s
2
 
7.00 
0.00 – 7.99 
ACCEL 
RATE 1 
Acceleration rate limit 
m/s
2
 2.134 0.000 
– 
3.999 
N Y 
ft/s
2
 
3.00 
0.00 – 7.99 
DECEL 
RATE 1 
Deceleration rate limit 
m/s
2
 0.090 0.000 
– 
3.999 
N Y 
ft/s
3
 
8.0 
0.0 – 29.9 
ACCEL 
JERK IN 1 
Rate of increase of acceleration, up to ACCEL 
RATE, when increasing elevator speed 
m/s
3
 2.400 0.000 
– 
9.999 
N Y 
ft/s
3
 
8.0 
0.0 – 29.9 
ACCEL 
JERK OUT 1 
Rate of decrease of acceleration to zero when 
approaching contract elevator speed 
m/s
3
 2.400 0.000 
– 
9.999 
N Y 
ft/s
3
 
8.0 
0.0 – 29.9 
DECEL 
JERK IN 1 
Rate of increase of deceleration, up to DECEL 
RATE, when decreasing elevator speed 
m/s
3
 2.400 0.000 
– 
9.999 
N Y 
ft/s
3
 
8.0 
0.0 – 29.9 
DECEL 
JERK OUT 1 
Rate of decrease of deceleration to zero when 
slowing the elevator to leveling speed 
m/s
3
 2.400 0.000 
– 
9.999 
N Y 
ft/s
2
 
3.00 
0.00 – 7.99 
ACCEL 
RATE 2 
Acceleration rate limit 
m/s
2
 0.090 0.000 
– 
3.999 
N Y 
ft/s
2
 
3.00 
0.00 – 7.99 
DECEL 
RATE 2 
Deceleration rate limit 
m/s
2
 0.090 0.000 
– 
3.999 
N Y 
ft/s
3
 
8.0 
0.0 – 29.9 
ACCEL 
JERK IN 2 
Rate of increase of acceleration, up to ACCEL 
RATE, when increasing elevator speed 
m/s
3
 2.400 0.000 
– 
9.999 
N Y 
ft/s
3
 
8.0 
0.0 – 29.9 
ACCEL 
JERK OUT 2 
Rate of decrease of acceleration to zero when 
approaching contract elevator speed 
m/s
3
 2.400 0.000 
– 
9.999 
N Y 
ft/s
3
 
8.0 
0.0 – 29.9 
DECEL 
JERK IN 2 
Rate of increase of deceleration, up to DECEL 
RATE, when decreasing elevator speed 
m/s
3
 2.400 0.000 
– 
9.999 
N Y 
ft/s
3
 
8.0 
0.0 – 29.9 
DECEL 
JERK OUT 2 
Rate of decrease of deceleration to zero when 
slowing the elevator to leveling speed 
m/s
3
 2.400 0.000 
– 
9.999 
N Y 
ft/s
2
 
3.00 
0.00 – 7.99 
ACCEL 
RATE 3 
Acceleration rate limit 
m/s
2
 0.090 0.000 
– 
3.999 
N Y 
ft/s
2
 
3.00 
0.00 – 7.99 
DECEL 
RATE 3 
Deceleration rate limit 
m/s
2
 0.090 0.000 
– 
3.999 
N Y 
ft/s
3
 
8.0 
0.0 – 29.9 
ACCEL 
JERK IN 3 
Rate of increase of acceleration, up to ACCEL 
RATE, when increasing elevator speed 
m/s
3
 2.400 0.000 
– 
9.999 
N Y 
ft/s
3
 
8.0 
0.0 – 29.9 
ACCEL 
JERK OUT 3 
Rate of decrease of acceleration to zero when 
approaching contract elevator speed 
m/s
3
 2.400 0.000 
– 
9.999 
N Y 
ft/s
3
 
8.0 
0.0 – 29.9 
DECEL 
JERK IN 3 
Rate of increase of deceleration, up to DECEL 
RATE, when decreasing elevator speed 
m/s
3
 2.400 0.000 
– 
9.999 
N Y 
ft/s
3
 
8.0 
0.0 – 29.9 
DECEL 
JERK OUT 3 
Rate of decrease of deceleration to zero when 
slowing the elevator to leveling speed 
m/s
3
 2.400 0.000 
– 
9.999 
N Y 
 
Table 5: S-Curves A2 Submenu