Sun Microsystems 3900 Series Manuel D’Utilisation

Page de 162
24
Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002
FIGURE 3-2
Data Host Notification of Severe Link Error
FIGURE 3-3
Storage Service Processor Notification
Note –
An A1/B1 FC link error can cause a port in
sw1a
or
sw1b
to change state.
Site     : FSDE LAB Broomfield CO
Source   : diag.xxxxx.xxx.com
Severity : Normal
Category : Message     Key: message:diag.xxxxx.xxx.com
EventType: LogEvent.driver.MPXIO_offline
EventTime: 01/08/2002 14:48:02
Found 2 ’driver.MPXIO_offline’ warning(s) in logfile: /var/adm/messages on
diag.xxxxx.xxx.com (id=80fee746):
Jan 8 14:47:07  WWN:2b000060220041f9    diag.xxxxx.xxx.com mpxio: [ID
779286 kern.info] /scsi_vhci/ssd@g29000060220041f96257354230303053
(ssd19) multipath status: degraded, path /pci@6,4000/SUNW,qlc@3/fp@0,0
(fp1) to target address: 2b000060220041f9,1 is offline
Jan 8 14:47:07  WWN:2b000060220041f9    diag.xxxxx.xxx.com mpxio: [ID
779286 kern.info] /scsi_vhci/ssd@g29000060220041f96257354230303052
(ssd18) multipath status: degraded, path /pci@6,4000/SUNW,qlc@3/fp@0,0
(fp1) to target address: 2b000060220041f9,0 is offline
Site     : FSDE LAB Broomfield CO
Source   : diag.xxxxx.xxx.com
Severity : Normal
Category : Switch     Key: switch:100000c0dd0057bd
EventType: StateChangeEvent.X.port.6
EventTime: 01/08/2002 14:54:20
’port.6’ in SWITCH diag-sw1a (ip=192.168.0.30) is now Unknown (status-
state changed from ’Online’ to ’Admin’):