Sun Microsystems 3900 Series Manuel D’Utilisation

Page de 162
26
Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002
An error in the A1/B1 FC link can also cause a device to enter the “unusable” state
in
cfgadm
. In this case, the output for
luxadm -e port
will show that a device that
was “connected” changed to an “unconnected” state.
CODE EXAMPLE 3-2
cfgadm -al Display
FRU Tests Available for A1/B1 FC Link Segment
HBA—
qlctest
(1M)
A
vailable only if the Storage Automated Diagnostic Environment is installed
on a data host
C
auses HBA to go “offline” and “online” during tests
Switch —
switchtest
(1M)
C
an be run while the link is still cabled and online (connected to HBA)
You must specify a payload of 200 bytes or less when testing the A1/B1 FC
link, while the link is connected to the HBA (limitation in HBA ASIC).
Can be run only from the Storage Service Processor
The
dev
option to
switchtest
is in the following format:
Port:IP-Address:FCAddress
The
FCAddress
can be set to 0x0
...
# cfgadm -al
Ap_Id
Type
Receptacle
Occupant
Condition
c0
scsi-bus
connected
configured
unknown
c0::dsk/c0t0d0
disk
connected
configured
unknown
c0::dsk/c0t1d0
disk
connected
configured
unknown
c1
scsi-bus
connected
configured
unknown
c1::dsk/c1t6d0
CD-ROM
connected
configured
unknown
c2
fc-fabric
connected
configured
unknown
c2::210100e08b23fa25
unknown
connected
unconfigured unknown
c2::2b000060220041f4
disk
connected
configured
unknown
c3
fc-fabric
connected
configured
unknown
c3::2b000060220041f9
disk
connected
configured
unusable
c4
fc-private
connected
unconfigured unknown
c5
fc
connected
unconfigured unknown