INPut Subsystem
2–122
TVS600 & TVS600A Command Reference
INPut:COUPling
INPut:COUPling?
INPut:COUPling?
Sets or queries the type of signal coupling for the specified input channel. When
AC coupled and INPut:IMPedance is set to 1 M
AC coupled and INPut:IMPedance is set to 1 M
W, frequencies below 10 Hz are
attenuated. When AC coupled and INPut:IMPedance is set to 50
W, frequencies
below 200 kHz are attenuated. Setting COUPling to GROund connects the input
of the amplifier to ground and presents a high impedance to the incoming signal.
of the amplifier to ground and presents a high impedance to the incoming signal.
INPut<n>:COUPling <coupling>
INPut<n>:COUPling?
<n> (Channel Number)
1
Query response
1
2
3
4
2
3
4
Not applicable
1
The input channel number <n> is used by the commands INPut<n> and VOLTage<n>.
If you omit <n>, the default is channel 1.
If you omit <n>, the default is channel 1.
<coupling>
Query Response
AC
DC
GROund
DC
GROund
AC
DC
GRO
DC
GRO
DC
Execution Error –141, “Invalid character data, CALC1:WMC FTM”
Attempted to set coupling to an illegal value.
Attempted to set coupling to an illegal value.
Execution Error –241, “Hardware missing”
Attempted to program INPut3 or INPut4 on an
instrument configured with two channels.
Attempted to program INPut3 or INPut4 on an
instrument configured with two channels.
None
Command:
INP1:COUP AC
Query:
INP1:COUP?
Response:
AC
Syntax
Parameters
Reset Value
Errors and Events
Dependencies