Tektronix TVS600 & TVS600A Series Manuel D’Utilisation

Page de 410
SYSTem Subsystem
2–186
TVS600 & TVS600A Command Reference
None
None
Command:
SYSTem:AUT:TRIG CHAN
TRIGger:LEVel
SYSTem:AUToset:VOLTage
SYSTem:AUToset:SWEep
SYSTem:AUToset:VOLTage
TVS600A Models Only
Sets VOLTage:RANGe:UPPer and VOLTage:RANGe:LOWer so that the
incoming signal fills the center 90% of the peak to peak range.
Multiple acquisitions of an arbitrary period of 20ms will be acquired with peak
detect circuits enabled to find the peaks of the signal. This implies that the
incoming signal should be a repetitive 50Hz signal or faster.
It is the responsibility of the host application to preset all related settings such as
bandwidth filters, couplings, vertical settings, and so on.
After autoset completes, the host application can query VOLTage:RANGe:UPPer
and LOWer or VOLTage:RANGe PTPeak and OFFSet to find out what was
done.
SYSTem:AUToset:VOLTage <channel>
<channel>
Query response
CHAN[1]
CHAN2
CHAN3
CHAN4
Not applicable
None
Not applicable
Command Error –141, “Invalid character data”
Attempted to autoset IMMediate or any other illegal value.
Errors and Events
Dependencies
Examples
Related Commands
Syntax
Parameters
Suffix Units and
Multipliers
Reset Value
Errors and Events