Tektronix TVS600 & TVS600A Series Manuel D’Utilisation

Page de 410
TRIGger:B Subsystem
2–252
TVS600 & TVS600A Command Reference
TRIGger:B:FILTer:HPASs
TRIGger:B:FILTer:HPASs?
Sets or queries the state of the 50 kHz high pass filter for the B trigger circuit.
The HPASs filter attenuates components of the trigger signal below 50 kHz.
HPASs can only be used when AC coupled and with TRIGger:SOURce set to
INTernal. Only one trigger filter (i.e., LPAS, HPAS, or NREJ) may be enabled at
a time.
The INPut:FILTer is separate from the trigger filter and is located before the
trigger pickoff in the signal path.
TRIGger:B:FILTer:HPASs[:STATe] <boolean>
TRIGger:B:FILTer:HPASs[:STATe]?
<boolean>
Query response
<NRf >
1 or ON
0 or OFF
<NR1>
1
0
0
None
Enabling the high pass filter sets TRIGger:B:COUPling to AC and TRIG-
ger:B:FILTer:NREJect to OFF.
When TRIGger:A:SOURce and TRIGger:B:SOURce are set to the same signal,
changing HPAS for one will change HPAS for the other.
Command:
TRIG:B:FILT:HPAS ON
Query:
TRIG:B:FILT:HPAS?
Response:
1
TRIGger:B:COUPling
TRIGger:B:FILTer[:LPASs]
TRIGger:B:FILTer:NREJect
INPut:FILTer
Syntax
Parameters
Reset Value
Errors and Events
Dependencies
Examples
Related Commands