Tektronix TVS600 & TVS600A Series Manuel D’Utilisation

Page de 410
TRIGger:LOGic Subsystem
2–260
TVS600 & TVS600A Command Reference
TRIGger:LOGic:CLASs
TRIGger:LOGic:CLASs?
TVS600A Models Only
Sets or queries the class of logic triggering selected. PATTern: the instrument
triggers when the specified logical combination of channels 1, 2, 3 and 4 are met.
STATe: the instrument triggers when the specified conditions of channels 1, 2
and 3 are met at the same time a transition occurs on channel 4.
:A is a predefined alias for :SEQuence[1].
This command only has effect when TRIGger:TYPE is LOGic.
TRIGger:LOGic:CLASs STATE is not available when the instrument is
configured with two channels.
TRIGger[:A]:LOGic:CLASs <logic_class>
TRIGger[:A]:LOGic:CLASs?
<logic_class>
Query response
PATTern
STATe
PATT
STAT
None
PATT
Command Error –141, “Invalid character data”
Attempted to set class to an illegal value.
Execution Error –241, “Hardware missing”
Attempted to set class to STATe when the 
instrument is configured with two channels.
None
Command:
TRIG:LOG:CLAS STATe
Query:
TRIG:LOG:CLAS?
Response:
STAT
Syntax
Parameters
Suffix Units and
Multipliers
Reset Value
Errors and Events
Dependencies
Examples