Tektronix TVS600 & TVS600A Series Manuel D’Utilisation

Page de 410
TRIGger:TRANsition Subsystem
2–300
TVS600 & TVS600A Command Reference
TRIGger:TRANsition:THReshold:HIGH
TRIGger:TRANsition:THReshold:HIGH?
TVS600A Models Only
Sets or queries the high threshold for transition triggering.
:A is a predefined alias for :SEQuence[1].
The minimum and maximum values for threshold are VOLT:RANG:OFFS +/–
VOLT:RANG:PTP (in VOLT:RANG:PTP * 0.002 steps).
This command only has effect when TRIGger:TYPE is TRANsition.
TRIGger[:A]:TRANsition:THReshold:HIGH <level>
TRIGger[:A]:TRANsition:THReshold:HIGH?
<level>
Query response
<NRf>
MINimum
MAXimum
<NR3>
<See comments>
<See comments>
V (default), MV, or UV
0.0E+0
Execution Error –222, “Data out of range”
Attempted to set threshold to an illegal value.
None
Command:
TRIG:TRAN:THR:HIGH 1.0
Query:
TRIG:TRAN:THR:HIGH?
Response:
1.0E+0
TRIGger:TYPE
TRIGger:TRANsition:THReshold:LOW
Syntax
Parameters
Suffix Units and
Multipliers
Reset Value
Errors and Events
Dependencies
Examples
Related Commands