Tektronix TVS600 & TVS600A Series Manuel D’Utilisation

Page de 410
IEEE 488.2 Common Commands
TVS600 & TVS600A Command Reference
2–325
*STB? (Query Only)
Returns the contents of the Status Byte Register as a decimal sum of all set
events. You can get a chronological list of events from the Status Queue using
the SYSTem:ERRor? query. Table 2–7 describes the bit assignments in the
Status Byte Register. For a complete description of the status and events
reporting system, see the TVS600 & TVS600A Series Waveform Analyzers User
Manual
.
Table 2–7: The Status Byte Register 
Bit
Decimal 
Value
Function
0–1
Not used.
2
4
Error/Event Queue not empty indicates that the error/event queue
contains information and is waiting to be read.
3
8
Questionable Event Status indicates that the quality of result data
or of an operation is questionable.
4
16
Message Available (MAV) shows that data is available in the
Output Queue.
5
32
Event Status Bit indicates that one or more events have occurred
in the Standard Event Status Register.
6
64
Master Summary Status (MSS) is a summary bit that indicates
other bits in the Status Byte Register are set.
7 (MSB)
128
Operation Event Register indicates that the waveform analyzer is
busy performing a normal operation such as acquiring a waveform.
<event>
Query response
Not applicable
<NR1>
Not applicable
None
Reading this register does not clear it.
Query:
Syntax
Parameters
Reset Value
Errors and Events
Dependencies
Examples