6. SERIAL PORT 
 
The evalboard is equipped with a serial port connector, which is linked to UART1 (SCI1) 
of EM250. The S1 switch has to be set as follows: 
 
UART1 
active 
1 2 3 4 5 6 7 8 
S1 
settings 
ON 
off 
ON 
off  off off off off 
                           (Table 3)  
7. RESET 
 
Reset of the boards on A,B,C or D can be done with the button named “RESET” next to 
the USB socket. 
 
 
8. OPERATION AND PROGRAMMING  
 
8.1.   SERIAL COMMUNICATION AND EMBEDDED BOOTLOADER 
As a first step connect the testboards with the serial cables to 1 or 2 pc´s running 
terminal programs (for example Hyperterminal) with the following communication 
settings:  
 
 
115200bps,8,parity no, Stoppbits 1, no flow control 
After a hardware RESET and hitting the >return< key the terminal window of the PC 
connected to the RS232 interface of the ISM RF transceiver testboard should display 
Ember Range Test Application v2.0 
Oct 1 2006 
 
 
Set to channel 0x0F 
In order to do testing of basic hardware performance you could now proceed with 
commands  described in chapter 
could load an image file to PAN4570 as well. The chapter 0 describes loading the 
>simple-lighting< application from EmberZNet 2.5.0.   
 
Launch the embedded bootloader typing in >bootload< and press the. The display  now  
should read 
EM250 Bootloader v20 b01 
1. upload ebl 
2. run 
3. ebl info 
>BL 
Typing in >2< and hitting the >return< key would result in running the Ember
TM
 Rangetest 
software again.