Panasonic PAN4570 Manuel D’Utilisation
CLASSIFICATION
Einstufung
Einstufung
No.
DS-Eval4570-2400
DS-Eval4570-2400
REV.
C
SUBJECT
Thema
Thema
EvalBoard PAN4570
PAGE
Seite
Seite
8 of 20
CUSTOMER’S CODE
EvalPAN4570
EvalPAN4570
PANASONIC’S CODE
DATE
Datum
Datum
06.11.2006
European Technology Center
Panasonic Electronic Devices (EUROPE) GmbH
APPROVED
genehmigt
CHECKED
geprüft
DESIGNED
Erstellt
6. SERIAL PORT
The evalboard is equipped with a serial port connector, which is linked to UART1 (SCI1)
of EM250. The S1 switch has to be set as follows:
UART1
active
active
1 2 3 4 5 6 7 8
S1
settings
settings
ON
off
ON
off off off off off
(Table 3)
7. RESET
Reset of the boards on A,B,C or D can be done with the button named “RESET” next to
the USB socket.
Reset of the boards on A,B,C or D can be done with the button named “RESET” next to
the USB socket.
8. OPERATION AND PROGRAMMING
8.1. SERIAL COMMUNICATION AND EMBEDDED BOOTLOADER
As a first step connect the testboards with the serial cables to 1 or 2 pc´s running
terminal programs (for example Hyperterminal) with the following communication
settings:
terminal programs (for example Hyperterminal) with the following communication
settings:
115200bps,8,parity no, Stoppbits 1, no flow control
After a hardware RESET and hitting the >return< key the terminal window of the PC
connected to the RS232 interface of the ISM RF transceiver testboard should display
connected to the RS232 interface of the ISM RF transceiver testboard should display
Ember Range Test Application v2.0
Oct 1 2006
Oct 1 2006
Set to channel 0x0F
In order to do testing of basic hardware performance you could now proceed with
commands described in chapter
commands described in chapter
could load an image file to PAN4570 as well. The chapter 0 describes loading the
>simple-lighting< application from EmberZNet 2.5.0.
Launch the embedded bootloader typing in >bootload< and press the. The display now
should read
>simple-lighting< application from EmberZNet 2.5.0.
Launch the embedded bootloader typing in >bootload< and press the. The display now
should read
EM250 Bootloader v20 b01
1. upload ebl
2. run
3. ebl info
>BL
1. upload ebl
2. run
3. ebl info
>BL
Typing in >2< and hitting the >return< key would result in running the Ember
TM
Rangetest
software again.