DELL R730xd Manuel D’Utilisation

Page de 208
7. Ensure that all network cables are of the proper type and do not exceed the maximum length.
Next steps
If all troubleshooting fails, see 
.
Troubleshooting a wet system
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only 
perform troubleshooting and simple repairs as authorized in your product documentation, or as 
directed by the online or telephone service and support team. Damage due to servicing that is 
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions 
that came with the product.
Steps
1.
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
2. Remove the system cover.
3. Remove the following components from the system:
• hard drives
• hard-drive backplane
• USB memory key
• hard-drive tray
• cooling shroud
• expansion-card risers (if present)
• expansion cards
• power supply unit(s)
• cooling-fan assembly (if present)
• cooling fans
• processor(s) and heat sink(s)
• memory modules
4. Let the system dry thoroughly for at least 24 hours.
5. Reinstall the components you removed in step 3.
6. Install the system cover.
7. Turn on the system and attached peripherals.
.
8. If the system starts properly, shut down the system, and reinstall all the expansion cards that you 
removed.
.
Next steps
If the tests fail, see 
183